| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Delta Electronics DTM Soft deserializes objects, which could allow an attacker to execute arbitrary code. |
| CWE-502: Deserialization of untrusted data vulnerability exists that could lead to loss of confidentiality, integrity
and potential remote code execution on workstation when a non-admin authenticated user opens a malicious
project file. |
| A deserialization of untrusted data vulnerability exists in NI DAQExpress that may result in remote code execution. Successful exploitation requires an attacker to get a user to open a specially crafted project file. This vulnerability affects DAQExpress 5.1 and prior versions. Please note that DAQExpress is an EOL product and will not receive any updates. |
| A deserialization of untrusted data vulnerability exists in NI G Web Development Software that may result in arbitrary code execution. Successful exploitation requires an attacker to get a user to open a specially crafted project file. This vulnerability affects G Web Development Software 2022 Q3 and prior versions. |
| A vulnerability was found in running-elephant Datart 1.0.0-rc3. It has been rated as critical. Affected by this issue is the function extractModel of the file /import of the component File Upload. The manipulation of the argument file leads to deserialization. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| WiX toolset lets developers create installers for Windows Installer, the Windows installation engine. The custom action behind WiX's `RemoveFolderEx` functionality could allow a standard user to delete protected directories. `RemoveFolderEx` deletes an entire directory tree during installation or uninstallation. It does so by recursing every subdirectory starting at a specified directory and adding each subdirectory to the list of directories Windows Installer should delete. If the setup author instructed `RemoveFolderEx` to delete a per-user folder from a per-machine installer, an attacker could create a directory junction in that per-user folder pointing to a per-machine, protected directory. Windows Installer, when executing the per-machine installer after approval by an administrator, would delete the target of the directory junction. This vulnerability is fixed in 3.14.1 and 4.0.5. |
| FreePBX Endpoint Manager is a module for managing telephony endpoints in FreePBX systems. Versions prior to 16.0.96 and 17.0.1 through 17.0.9 have a weak default password. By default, this is a 6 digit numeric value which can be brute forced. (This is the app_password parameter). Depending on local configuration, this password could be the extension, voicemail, user manager, DPMA or EPM phone admin password. This issue is fixed in versions 16.0.96 and 17.0.10. |
| A vulnerability in the boot process of Cisco Access Point (AP) Software could allow an unauthenticated, physical attacker to bypass the Cisco Secure Boot functionality and load a software image that has been tampered with on an affected device.
This vulnerability exists because unnecessary commands are available during boot time at the physical console. An attacker could exploit this vulnerability by interrupting the boot process and executing specific commands to bypass the Cisco Secure Boot validation checks and load an image that has been tampered with. This image would have been previously downloaded onto the targeted device. A successful exploit could allow the attacker to load the image once. The Cisco Secure Boot functionality is not permanently compromised. |
| V-SOL GPON/EPON OLT Platform 2.03 contains an unauthenticated information disclosure vulnerability that allows attackers to download configuration files via direct object reference. Attackers can retrieve sensitive configuration data by sending HTTP GET requests to the usrcfg.conf endpoint, potentially enabling authentication bypass and system access. |
| TG8 Firewall exposes a directory such as /data/ over HTTP without authentication. This directory stores credential files for previously logged-in users. A remote unauthenticated attacker can enumerate and download files within the directory to obtain valid account usernames and passwords, leading to loss of confidentiality and further unauthorized access. |
| A vulnerability has been identified in CPCI85 Central Processing/Communication (All versions < V05.30). The affected devices contain a secure element which is connected via an unencrypted SPI bus. This could allow an attacker with physical access to the SPI bus to observe the password used for the secure element authentication, and then use the secure element as an oracle to decrypt all encrypted update files. |
| Certain errors of the upstream libraries will insert sensitive information in the OTRS or ((OTRS)) Community Edition log mechanism and mails send to the system administrator.
This issue affects:
* OTRS 7.0.X
* OTRS 8.0.X
* OTRS 2023.X
* OTRS 2024.X
* ((OTRS)) Community Edition: 6.0.x
Products based on the ((OTRS)) Community Edition also very likely to be affected |
| Insufficiently Protected Credentials in LDAP in Konica Minolta bizhub 227 Multifunction printers version GCQ-Y3 or earlier allows an attacker can reconfigure the target device to use an external LDAP service controlled by the attacker. If an LDAP password is set on the target device, the attacker can force the target device to authenticate to the attacker controlled LDAP service. This will allow the attacker to capture the plaintext password of the configured LDAP service. |
| The ReadFile endpoint of the firmware for Mennekes Smart / Premium Chargingpoints can be abused to read arbitrary files from the underlying OS. |
| A low privileged remote attacker with file access can replace a critical file used by the arp-preinit script to get read, write and execute access to any file on the device. |
| Weak Password Requirements vulnerability in Mitsubishi Electric Corporation photovoltaic system monitor “EcoGuideTAB” PV-DR004J all versions and PV-DR004JA all versions allows an attacker within the Wi-Fi communication range between the units of the product (measurement unit and display unit) to derive the password from the SSID. In addition, if the product is configured to enable the individual air conditioner control function, an attacker who has access to the Wi-Fi communication between the units by exploiting this vulnerability may be able to execute ECHONET Lite commands to perform operations such as turning the air conditioner on or off and changing the set temperature. The individual air conditioner control function is available only in display unit version 02.00.01 or later and measurement unit version 02.03.01 or later. The affected products discontinued in 2015, support ended in 2020. |
| A remote code execution (RCE) vulnerability exists in the ms-swift project version 3.3.0 due to unsafe deserialization in tests/run.py using yaml.load() from the PyYAML library (versions = 5.3.1). If an attacker can control the content of the YAML configuration file passed to the --run_config parameter, arbitrary code can be executed during deserialization. This can lead to full system compromise. The vulnerability is triggered when a malicious YAML file is loaded, allowing the execution of arbitrary Python commands such as os.system(). It is recommended to upgrade PyYAML to version 5.4 or higher, and to use yaml.safe_load() to mitigate the issue. |
| The exposure of credentials in the call forwarding configuration module in MeetMe products in versions prior to 2024-09 allows an attacker to gain access to some important assets via configuration files. |
| Information disclosure and exposure of authentication FTP credentials over the debug port 1604 in the MINOVA TTA service. This allows unauthenticated remote access to an active FTP account containing sensitive internal data and import structures. In environments where this FTP server is part of automated business processes (e.g. EDI or data integration), this could lead to data manipulation, extraction, or abuse. Debug ports 1602, 1603 and 1636 also expose service architecture information and system activity logs |
| By using the "uscan" protocol provided by the eSCL specification, an attacker can discover the serial number of multi-function printers that implement the Brother-provided firmware. This serial number can, in turn, can be leveraged by the flaw described by CVE-2024-51978 to calculate the default administrator password. This flaw is similar to CVE-2024-51977, with the only difference being the protocol by which an attacker can use to learn the remote device's serial number. The eSCL/uscan vector is typically only exposed on the local network. Any discovery service that implements the eSCL specification can be used to exploit this vulnerability, and one such implementation is the runZero Explorer. Changing the default administrator password will render this vulnerability virtually worthless, since the calculated default administrator password would no longer be the correct password. |