Export limit exceeded: 386970 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Search

Search Results (36326 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2023-37649 1 Agentejo 1 Cockpit 2024-11-21 7.5 High
Incorrect access control in the component /models/Content of Cockpit CMS v2.5.2 allows unauthorized attackers to access sensitive data.
CVE-2023-37563 1 Elecom 10 Wrc-1167febk-a, Wrc-1167febk-a Firmware, Wrc-1167febk-s and 7 more 2024-11-21 6.5 Medium
ELECOM wireless LAN routers are vulnerable to sensitive information exposure, which allows a network-adjacent unauthorized attacker to obtain sensitive information. Affected products and versions are as follows: WRC-1167GHBK-S v1.03 and earlier, WRC-1167GEBK-S v1.03 and earlier, WRC-1167FEBK-S v1.04 and earlier, WRC-1167GHBK3-A v1.24 and earlier, WRC-1167FEBK-A v1.18 and earlier, WRC-F1167ACF2 all versions, WRC-600GHBK-A all versions, WRC-733FEBK2-A all versions, WRC-1467GHBK-A all versions, WRC-1467GHBK-S all versions, WRC-1900GHBK-A all versions, and WRC-1900GHBK-S all versions.
CVE-2023-37559 1 Codesys 16 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 13 more 2024-11-21 6.5 Medium
After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37558
CVE-2023-37558 1 Codesys 16 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 13 more 2024-11-21 6.5 Medium
After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37559
CVE-2023-37556 1 Codesys 16 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 13 more 2024-11-21 6.5 Medium
In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37552, CVE-2023-37553, CVE-2023-37554 and CVE-2023-37555.
CVE-2023-37555 1 Codesys 16 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 13 more 2024-11-21 6.5 Medium
In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37552, CVE-2023-37553, CVE-2023-37554 and CVE-2023-37556.
CVE-2023-37554 1 Codesys 16 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 13 more 2024-11-21 6.5 Medium
In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37552, CVE-2023-37553, CVE-2023-37555 and CVE-2023-37556.
CVE-2023-37553 1 Codesys 16 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 13 more 2024-11-21 6.5 Medium
In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37552, CVE-2023-37554, CVE-2023-37555 and CVE-2023-37556.
CVE-2023-37552 1 Codesys 16 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 13 more 2024-11-21 6.5 Medium
In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37553, CVE-2023-37554, CVE-2023-37555 and CVE-2023-37556.
CVE-2023-37550 1 Codesys 16 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 13 more 2024-11-21 6.5 Medium
In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37548 and CVE-2023-37549.
CVE-2023-37549 1 Codesys 16 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 13 more 2024-11-21 6.5 Medium
In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37548 and CVE-2023-37550
CVE-2023-37548 1 Codesys 16 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 13 more 2024-11-21 6.5 Medium
In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37549 and CVE-2023-37550
CVE-2023-37547 1 Codesys 16 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 13 more 2024-11-21 6.5 Medium
In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546, CVE-2023-37548, CVE-2023-37549 and CVE-2023-37550
CVE-2023-37546 1 Codesys 16 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 13 more 2024-11-21 6.5 Medium
In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37547, CVE-2023-37548, CVE-2023-37549 and CVE-2023-37550
CVE-2023-37545 1 Codesys 16 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 13 more 2024-11-21 6.5 Medium
In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37546, CVE-2023-37547, CVE-2023-37548, CVE-2023-37549, CVE-2023-37550
CVE-2023-37521 1 Hcltechsw 1 Bigfix Bare Osd Metal Server Webui 2024-11-21 2.3 Low
HCL BigFix Bare OSD Metal Server WebUI version 311.19 or lower can sometimes include sensitive information in a query string which could allow an attacker to execute a malicious attack.
CVE-2023-37513 1 Hcltech 1 Traveler To Do 2024-11-21 3.3 Low
When the app is put to the background and the user goes to the task switcher of iOS, the app snapshot is not blurred which may reveal sensitive information.
CVE-2023-37512 1 Hcltech 1 Traveler Companion 2024-11-21 3.3 Low
When the app is put to the background and the user goes to the task switcher of iOS, the app snapshot is not blurred which may reveal sensitive information.
CVE-2023-37511 1 Hcltech 1 Traveler To Do 2024-11-21 3.5 Low
If certain App Transport Security (ATS) settings are set in a certain manner, insecure loading of web content can be achieved.
CVE-2023-37498 1 Hcltech 1 Unica 2024-11-21 8.1 High
A user is capable of assigning him/herself to arbitrary groups by reusing a POST request issued by an administrator.  It is possible that an attacker could potentially escalate their privileges.