| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Missing Authentication for Critical Function vulnerability in GE Vernova Enervista UR Setup application allows Authentication Bypass due to a missing SSH server authentication. Since the client connection is not authenticated, an attacker may perform a man-in-the-middle attack on the network. |
| Missing authentication for critical function issue exists in I-O DATA network attached hard disk 'HDL-T Series' firmware Ver.1.21 and earlier. If exploited, a remote unauthenticated attacker may change the product settings. |
| Simofa is a tool to help automate static website building and deployment. Prior to version 0.2.7, due to a design mistake in the RouteLoader class, some API routes may be publicly accessible when they should require authentication. This vulnerability has been patched in v0.2.7. |
| Delta Electronics DIAView has an authentication bypass vulnerability. |
| The paths "/cgi-bin/CliniNET.prd/utils/userlogstat.pl", "/cgi-bin/CliniNET.prd/utils/usrlogstat.pl", and "/cgi-bin/CliniNET.prd/utils/dblogstat.pl" expose data containing session IDs. |
| The wallet has an authentication bypass vulnerability that allows access to specific pages. |
| Incorrect access control in the component l_0_0.xml of TP-Link ARCHER-C7 v5 allows attackers to access sensitive information. |
| The exos 9300 application can be used to configure Access Managers (e.g. 92xx, 9230 and 9290). The configuration is done in a graphical user interface on the dormakaba exos server. As soon as the save button is clicked in exos 9300, the whole configuration is sent to the selected Access Manager via SOAP. The SOAP request is sent without any prior authentication or authorization by default. Though authentication and authorization can be configured using IPsec for 92xx-K5 devices and mTLS for 92xx-K7 devices, it is not enabled by default and must therefore be activated with additional steps.
This insecure default allows an attacker with network level access to completely control the whole environment. An attacker is for example easily able to conduct the following tasks without prior authentication:
- Re-configure Access Managers (e.g. remove alarming system requirements)
- Freely re-configure the inputs and outputs
- Open all connected doors permanently
- Open all doors for a defined time interval
- Change the admin password
- and many more
Network level access can be gained due to an insufficient network segmentation as well as missing LAN firewalls. Devices with an insecure configuration have been identified to be directly exposed to the internet. |
| With address book access, SMB/FTP settings could be modified, redirecting scans and possibly capturing credentials. This requires enabled scan functions and printer access. |
| The affected products expose an unauthenticated Telnet-based command line interface that could allow an attacker to modify hardware configurations, manipulate data, or factory reset the device. |
| An issue in Casa Systems NTC-221 version 2.0.99.0 and before allows a remote attacker to execute arbitrary code via a crafted payload to the /www/cgi-bin/nas.cgi component. |
| An unauthenticated remote attacker may use the devices traffic capture without authentication to grab plaintext administrative credentials. |
| Missing authentication for critical function vulnerability exists in Rakuten Turbo 5G firmware version V1.3.18 and earlier. If this vulnerability is exploited, a remote unauthenticated attacker may update or downgrade the firmware on the device. |
| The Control-M/Agent is vulnerable to unauthenticated remote code execution, arbitrary file read and write and similar unauthorized actions when mutual SSL/TLS authentication is not enabled (i.e. in the default configuration).
NOTE:
* The vendor believes that this vulnerability only occurs when documented security best practices are not followed. BMC has always strongly recommended to use security best practices such as configuring SSL/TLS between Control-M Server and Agent.
* The vendor notifies that Control-M/Agent is not impacted in Control-M SaaS |
| A low privileged remote attacker may modify the boot mode configuration setup of the device, leading to modification of the firmware upgrade process or a denial-of-service attack. |
| CVE-2025-1701 is a high-severity vulnerability in the MIM Admin service. An attacker could exploit this vulnerability by sending a specially crafted request over the RMI interface to execute arbitrary code with the privileges of the MIM Admin service. The RMI interface is only accessible locally (listening on 127.0.0.1), limiting the attack vector to the local machine. This means that in a properly configured hospital environment, an attacker must have already compromised the network and additionally compromised the system where the MIM Admin service is running. From there, attackers with sufficient knowledge of MIM's implementation, library usage, and functionality with access to extend the MIM RMI library could force the MIM Admin service to run commands on the local machine with its privileges.
Users of MIM Software products exposed via RDP or multi-user application virtualization system should take note that the system being exposed is the environment hosting the virtualized MIM client.
This issue affects MIM Admin Service: before 7.2.13, 7.3.8, 7.4.3 |
| A client-side remote code execution vulnerability exists in Hanwha Techwin Smart Security Manager (SSM) versions 1.32 and 1.4, due to improper restrictions on the PUT method exposed by the bundled Apache ActiveMQ instance (running on port 8161). An attacker can exploit this flaw through a Cross-Origin Resource Sharing (CORS) bypass combined with JavaScript-triggered file uploads to the web server, ultimately resulting in arbitrary code execution with SYSTEM privileges.
This vulnerability bypasses the server-side mitigations introduced in ZDI-15-156 and ZDI-16-481 by shifting the exploitation to the client-side.
This product is now referred to as Hanwha Wisenet SSM and it is unknown if current versions are affected. |
| An unrestricted file upload vulnerability exists in Dell (acquired by Quest) KACE K1000 System Management Appliance version 5.0 - 5.3, 5.4 prior to 5.4.76849, and 5.5 prior to 5.5.90547 in the download_agent.php endpoint. An attacker can upload arbitrary PHP files to a temporary web-accessible directory, which are later executed through inclusion in backend code that loads files under attacker-controlled paths. |
| Missing authentication for critical function vulnerability exists in AssetView and AssetView CLOUD. If exploited, the files on the server where the product is running may be obtained and/or deleted by a remote unauthenticated attacker. |
| The embedded web server on the thermostat listed version ranges contain a vulnerability that allows unauthenticated attackers, either on the local area network or from the Internet via a router with port forwarding set up, to gain direct access to the thermostat's embedded web server and reset user credentials by manipulating specific elements of the embedded web interface. |