| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| The OTP Integration Kit for PingFederate fails to enforce HTTP method validation and state validation properly. The server advances the authentication state without verifying the OTP, thereby bypassing multi-factor authentication. |
| A potential missing authentication vulnerability was reported in some Lenovo Tablets that could allow an unauthorized user with physical access to modify Control Center settings if the device is locked when the "Allow Control Center access when locked" option is disabled. |
| Authentication Bypass
vulnerability in Hitachi Ops Center Analyzer on Linux, 64 bit (Hitachi Ops Center Analyzer detail view component), Hitachi Infrastructure Analytics Advisor on Linux, 64 bit (Hitachi Data Center Analytics
component
).This issue affects Hitachi Ops Center Analyzer: from 10.0.0-00 before 11.0.3-00; Hitachi Infrastructure Analytics Advisor: from 2.1.0-00 through 4.4.0-00. |
| Sensitive data disclosure and manipulation due to missing authentication. The following products are affected: Acronis Cyber Protect Cloud Agent (Linux, macOS, Windows) before build 39870, Acronis Cyber Protect 16 (Linux, macOS, Windows) before build 39938, Acronis Cyber Protect 15 (Linux, macOS, Windows) before build 41800. |
| WHILL Model C2 Electric Wheelchairs and Model F Power Chairs do not enforce authentication for Bluetooth connections. An attacker within range can pair with the device and issue movement commands, override speed restrictions, and manipulate configuration profiles without any credentials or user interaction. |
| An unauthenticated user with management network access can get and
modify the Radiflow iSAP Smart Collector (CentOS 7 - VSAP 1.20)
configuration. The device has two web servers that expose unauthenticated REST APIs on the management network (TCP
ports 8084 and 8086). An attacker can use these APIs to get access to all system settings, modify the configuration
and execute some commands (e.g., system reboot). |
| A code injection vulnerability exists in Yonyou UFIDA NC v6.5 and prior due to the exposure of the BeanShell testing servlet (bsh.servlet.BshServlet) without proper access controls. The servlet allows unauthenticated remote attackers to execute arbitrary Java code via the bsh.script parameter. This can be exploited to run system commands and ultimately gain full control over the target server. The issue is rooted in a third-party JAR component bundled with the application, and the servlet is accessible without authentication on vulnerable installations. Exploitation evidence was observed by the Shadowserver Foundation on 2025-02-05 UTC. |
| The MinigameCenter module has insufficient restrictions on loading URLs, which may lead to some information leakage. |
| An unauthenticated remote command execution vulnerability exists in Samsung WLAN AP WEA453e firmware prior to version 5.2.4.T1 via improper input validation in the “Tech Support” diagnostic functionality. The command1 and command2 POST or GET parameters accept arbitrary shell commands that are executed with root privileges on the underlying operating system. An attacker can exploit this by crafting a request that injects shell commands to create output files in writable directories and then access their contents via the download endpoint. This flaw allows complete compromise of the device without authentication. Exploitation evidence was observed by the Shadowserver Foundation on 2025-02-04 UTC. |
| A vulnerability in the handling of verify_mode = CERT_REQUIRED in the wolfssl Python package (wolfssl-py) causes client certificate requirements to not be fully enforced.
Because the WOLFSSL_VERIFY_FAIL_IF_NO_PEER_CERT flag was not included, the behavior effectively matched CERT_OPTIONAL: a peer certificate was verified if presented, but connections were incorrectly authenticated when no client certificate was provided.
This results in improper authentication, allowing attackers to bypass mutual TLS (mTLS) client authentication by omitting a client certificate during the TLS handshake.
The issue affects versions up to and including 5.8.2. |
| An unauthenticated command injection vulnerability exists in stamparm/maltrail (Maltrail) versions <=0.54. A remote attacker can execute arbitrary operating system commands via the username parameter in a POST request to the /login endpoint. This occurs due to unsafe handling of user-supplied input passed to subprocess.check_output() in core/http.py, allowing injection of shell metacharacters. Exploitation does not require authentication and commands are executed with the privileges of the Maltrail process. |
| A problem with missing authorization on SolaX Cloud platform allows taking over any SolaX solarpanel inverter of which the serial number is known. |
| A vulnerability was identified in huggingface LeRobot up to 0.3.3. Affected by this vulnerability is an unknown functionality of the file lerobot/common/robot_devices/robots/lekiwi_remote.py of the component ZeroMQ Socket Handler. The manipulation leads to missing authentication. The attack can only be initiated within the local network. The vendor was contacted early about this disclosure but did not respond in any way. |
| The MinigameCenter module has insufficient restrictions on loading URLs, which may lead to some information leakage. |
| A command injection vulnerability exists in the eScan Web Management Console version 5.5-2. The application fails to properly sanitize the 'pass' parameter when processing login requests to login.php, allowing an authenticated attacker with a valid username to inject arbitrary commands via a specially crafted password value. Successful exploitation results in remote code execution. Privilege escalation to root is possible by abusing the runasroot utility with mwconf-level privileges. |
| COMMAX Smart Home System is a smart IoT home solution that allows an unauthenticated attacker to disclose RTSP credentials in plain-text by exploiting the /overview.asp endpoint. Attackers can access sensitive information, including login credentials and DVR settings, by submitting a GET request to this endpoint. |
| Missing Authentication for Critical Function vulnerability in NEC Corporation Aterm WG2600HS Ver.1.7.2 and earlier, WF1200CRS Ver.1.6.0 and earlier, WG1200CRS Ver.1.5.0 and earlier, GB1200PE Ver.1.3.0 and earlier, WG2600HP4 Ver.1.4.2 and earlier, WG2600HM4 Ver.1.4.2 and earlier, WG2600HS2 Ver.1.3.2 and earlier, WX3000HP Ver.2.4.2 and earlier and WX4200D5 Ver.1.2.4 and earlier allows a attacker to get a Wi-Fi password via the network. |
| The web management interface of Okcat Parking Management Platform from ZONG YU has a Missing Authentication vulnerability, allowing unauthenticated remote attackers to directly access system functions. These functions include opening gates, viewing license plates and parking records, and restarting the system. |
| The specific APIs of Parking Management System from ZONG YU has a Missing Authentication vulnerability, allowing unauthenticated remote attackers to access specific APIs and operate system functions. These functions include opening gates and restarting the system. |
| A vulnerability has been identified in Perfect Harmony GH180 (All versions >= V8.0 < V8.3.3 with NXGPro+ controller manufactured between April 2020 to April 2025). The maintenance connection of affected devices fails to protect access to the device's control unit configuration. This could allow an attacker with physical access to the maintenance connection's door port to perform arbitrary configuration changes. |