| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An issue in the Sensor Settings of AVTECH Room Alert 4E v4.4.0 allows attackers to gain access to SMTP credentials in plaintext via a crafted AJAX request. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. |
| The MIB3 unit stores the synchronized phone contact book in clear-text, allowing an attacker with either code execution privilege on the system or physical access to the system to obtain vehicle owner's contact data.
The vulnerability was originally discovered in Skoda Superb III car with MIB3 infotainment unit OEM part number 3V0035820. The list of affected MIB3 OEM part numbers is provided in the referenced resources. |
| The Kiuwan Local Analyzer (KLA) Java scanning application contains several
hard-coded secrets in plain text format. In some cases, this can
potentially compromise the confidentiality of the scan results. Several credentials were found in the JAR files of the Kiuwan Local Analyzer.
The
JAR file "lib.engine/insight/optimyth-insight.jar" contains the file
"InsightServicesConfig.properties", which has the configuration tokens
"insight.github.user" as well as "insight.github.password" prefilled
with credentials. At least the specified username corresponds to a valid
GitHub account. The
JAR file "lib.engine/insight/optimyth-insight.jar" also contains the
file "es/als/security/Encryptor.properties", in which the key used for
encrypting the results of any performed scan.
This issue affects Kiuwan SAST: <master.1808.p685.q13371 |
| An issue was discovered in Newland Nquire 1000 Interactive Kiosk version NQ1000-II_G_V1.00.011, allows remote attackers to obtain sensitive information via cleartext credential storage in backup.htm component. |
| A vulnerability has been identified in POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q200 family (All versions >= V2.70 < V2.80). Affected devices store the password for the SMTP account as plain text. This could allow an authenticated local attacker to extract it and use the configured SMTP service for arbitrary purposes. |
| A vulnerability in the Palo Alto Networks PAN-OS® software enables unlicensed administrators to view clear-text data captured using the packet capture feature https://docs.paloaltonetworks.com/pan-os/11-0/pan-os-admin/monitoring/take-packet-captures/take-a-custom-packet-capture in decrypted HTTP/2 data streams traversing network interfaces on the firewall. HTTP/1.1 data streams are not impacted.
In normal conditions, decrypted packet captures are available to firewall administrators after they obtain and install a free Decryption Port Mirror license. The license requirement ensures that this feature can only be used after approved personnel purposefully activate the license. For more information, review how to configure decryption port mirroring https://docs.paloaltonetworks.com/network-security/decryption/administration/monitoring-decryption/configure-decryption-port-mirroring .
The administrator must obtain network access to the management interface (web, SSH, console, or telnet) and successfully authenticate to exploit this issue. Risk of this issue can be greatly reduced by restricting access to the management interface to only trusted administrators and from only internal IP addresses according to our recommended critical deployment guidelines https://live.paloaltonetworks.com/t5/community-blogs/tips-amp-tricks-how-to-secure-the-management-access-of-your-palo/ba-p/464431 .
Customer firewall administrators do not have access to the packet capture feature in Cloud NGFW. This feature is available only to authorized Palo Alto Networks personnel permitted to perform troubleshooting.
Prisma® Access is not impacted by this vulnerability. |
| ibm.ibm_zhmc is an Ansible collection for the IBM Z HMC. The Ansible collection "ibm.ibm_zhmc" writes password-like properties in clear text into its log file and into the output returned by some of its Ansible module in the following cases: 1. The 'boot_ftp_password' and 'ssc_master_pw' properties are passed as input to the zhmc_partition Ansible module. 2. The 'ssc_master_pw' and 'zaware_master_pw' properties are passed as input to the zhmc_lpar Ansible module. 3. The 'password' property is passed as input to the zhmc_user Ansible module (just in log file, not in module output). 4. The 'bind_password' property is passed as input to the zhmc_ldap_server_definition Ansible module. These properties appear in the module output only when they were specified in the module input and when creating or updating the corresponding resources. They do not appear in the output when retrieving facts for the corresponding resources. These properties appear in the log file only when the "log_file" module input parameter is used. By default, no log file is created. This issue has been fixed in ibm.ibm_zhmc version 1.9.3. Users are advised to upgrade. There are no known workarounds for this vulnerability. |
| This vulnerability exists in the TP-Link Archer C50 due to presence of terminal access on a serial interface without proper access control. An attacker with physical access could exploit this by accessing the UART shell on the vulnerable device. Successful exploitation of this vulnerability could allow the attacker to obtain Wi-Fi credentials of the targeted system. |
| This vulnerability exists in Digisol DG-GR6821AC Router due to storage of credentials and PINS without encryption in the device firmware. An attacker with physical access could exploit this vulnerability by extracting the firmware and reverse engineer the binary data to access the unencrypted data stored in the firmware of targeted device.
Successful exploitation of this vulnerability could allow the attacker to gain unauthorized access to the network of the targeted device. |
| An issue was discovered in Teledyne FLIR M300 2.00-19. User account passwords are encrypted locally, and can be decrypted to cleartext passwords using the utility umSetup. This utility requires root permissions to execute. |
| Medtronic MyCareLink Patient Monitor uses an unencrypted filesystem on internal storage, which allows an attacker with physical access to read and modify files.
This issue affects MyCareLink Patient Monitor models 24950 and 24952: before June 25, 2025 |
| The web server of the Access Manager offers a functionality to download a backup of the local database stored on the device. This database contains the whole configuration. This includes encrypted MIFARE keys, card data, user PINs and much more. The PINs are even stored unencrypted. Combined with the fact that an attacker can easily get access to the backup functionality by abusing the session management issue (CVE-2025-59101), or by exploiting the weak default password (CVE-2025-59108), or by simply setting a new password without prior authentication via the SOAP API (CVE-2025-59097), it is easily possible to access the sensitive data on the device. |
| A flaw was found in Ansible Automation Platform (AAP) where the Gateway API returns the client secret for certain GitHub Enterprise authenticators in clear text. This vulnerability affects administrators or auditors accessing authenticator configurations. While access is limited to privileged users, the clear text exposure of sensitive credentials increases the risk of accidental leaks or misuse. |
| In Unify CP IP Phone firmware 1.10.4.3, files are not encrypted and contain sensitive information such as the root password hash. |
| An issue in the SMTP Email Settings of AVTECH Room Alert 4E v4.4.0 allows attackers to gain access to credentials in plaintext via a passback attack. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. |
| The NMAP Importer service may expose data store credentials to authorized users of the Windows Registry.
|
| CWE-312: Cleartext Storage of Sensitive Information vulnerability exists that exposes test
credentials in the firmware binary |
| A security issue was discovered within the legacy Ansible playbook component of Verve Asset Manager, caused by plaintext secrets incorrectly stored when a playbook is running. This component has been retired and has been optional since the 1.36 release in 2024. |
| The YoSmart YoLink Smart Hub firmware 0382 is unencrypted, and data extracted from it can be used to determine network access credentials. |
| Infoblox BloxOne v2.4 was discovered to contain a business logic flaw due to thick client vulnerabilities. |