In the Linux kernel, the following vulnerability has been resolved:

batman-adv: tp_meter: directly shut down timer on cleanup

batadv_tp_sender_cleanup() was calling timer_delete_sync() followed by
timer_delete() to guard against the timer handler re-arming itself between
the two calls. This double-deletion hack relied on the sending status being
set to 0 to suppress re-arming.

Replace both calls with a single timer_shutdown_sync(). This function both
waits for any running timer callback to complete (like timer_delete_sync())
and permanently disarms the timer so it cannot be re-armed afterwards,
making re-arming prevention unconditional and self-documenting.

The re-arming property is also required because otherwise:

1. context 0 (batadv_tp_recv_ack()) checks in
batadv_tp_reset_sender_timer() if sending is still 1 -> it is
2. context 1 changes in batadv_tp_sender_shutdown() sending to 0 and in
this process forces the kthread to stop timer in
batadv_tp_sender_cleanup()
3. context 0 continues in batadv_tp_reset_sender_timer() and rearms the
timer -> but the reference for it is already gone

Project Subscriptions

Vendors Products
Linux Kernel Subscribe
Advisories

No advisories yet.

Fixes

Solution

No solution given by the vendor.


Workaround

No workaround given by the vendor.

History

Sun, 19 Jul 2026 16:15:00 +0000

Type Values Removed Values Added
Description In the Linux kernel, the following vulnerability has been resolved: batman-adv: tp_meter: directly shut down timer on cleanup batadv_tp_sender_cleanup() was calling timer_delete_sync() followed by timer_delete() to guard against the timer handler re-arming itself between the two calls. This double-deletion hack relied on the sending status being set to 0 to suppress re-arming. Replace both calls with a single timer_shutdown_sync(). This function both waits for any running timer callback to complete (like timer_delete_sync()) and permanently disarms the timer so it cannot be re-armed afterwards, making re-arming prevention unconditional and self-documenting. The re-arming property is also required because otherwise: 1. context 0 (batadv_tp_recv_ack()) checks in batadv_tp_reset_sender_timer() if sending is still 1 -> it is 2. context 1 changes in batadv_tp_sender_shutdown() sending to 0 and in this process forces the kthread to stop timer in batadv_tp_sender_cleanup() 3. context 0 continues in batadv_tp_reset_sender_timer() and rearms the timer -> but the reference for it is already gone
Title batman-adv: tp_meter: directly shut down timer on cleanup
First Time appeared Linux
Linux linux Kernel
CPEs cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*
Vendors & Products Linux
Linux linux Kernel
References

Projects

Sign in to view the affected projects.

cve-icon MITRE

Status: PUBLISHED

Assigner: Linux

Published:

Updated: 2026-07-19T15:40:01.172Z

Reserved: 2026-07-19T07:54:57.032Z

Link: CVE-2026-64093

cve-icon Vulnrichment

No data.

cve-icon NVD

No data.

cve-icon Redhat

No data.

cve-icon OpenCVE Enrichment

No data.

Weaknesses

No weakness.