| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| CWE-770: Allocation of Resources Without Limits or Throttling vulnerability exists that could cause denial of service of the OPC UA communication platform when a large number of OPC UA requests are sent to the platform. |
| CWE-564: SQL Injection: Hibernate vulnerability exists that could allow the injection of a malicious HQL query in the NetBotz database when a malicious user is logged into the NetBotz via the web-service interface or webui. |
| CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could allow an attacker to gain unauthorized access to a user account by performing an arbitrary number of authentication attempts when redirect handling is disabled. |
| CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause execution of Linux Operating system commands when a system back up is restored that has been maliciously modified. |
| The WP Fastest Cache WordPress plugin before 1.5.1 does not include a set of tracking-related query parameters in its page-cache key while still caching pages requested with them, allowing unauthenticated attackers to have a page rendered under their own request context stored under, and served from, the clean URL's cache entry to every subsequent visitor. |
| The KiviCare WordPress plugin before 4.5.5 does not perform authorization checks on some of its REST endpoints, allowing unauthenticated attackers to disclose the patient roster and, when a payment gateway is configured, the payment gateway secret key. |
| The MW WP Form WordPress plugin before 5.1.5 does not prevent shortcodes in user-submitted values from being executed when it merges those values into a message that it later processes for shortcodes, allowing unauthenticated users to run any shortcode registered on the site. Exploitation requires the site to have been configured to echo a submitted value back to the visitor after submission. |
| A denial-of-service security issue exists within ArmorStart® LT. The security issue stems from improper handling of a crafted HTTP PUT request sent to the embedded web server. This can result in a loss of web server availability |
| A denial-of-service security issue exists within FactoryTalk® Historian Machine Edition. A network adjacent attacker who is authenticated could send crafted requests to the web interface, resulting in buffer overflow conditions that may cause the device to crash and become unresponsive. |
| A denial-of-service security issue exists in the affected product. The security issue stems from a crafted CIP packet being sent crashing the module. The device requires a restart to recover. |
| A denial-of-service security issue exists within RSLinx® Classic. A crafted CIP packet can cause the RSLinx® Classic service to crash due to insufficient data length validation, requiring a restart of the service to recover. |
| A security issue exists within the Redundancy Module Configuration Tool. The RM3ConfigTool.exe binary searches directories in the system path for a required DLL, and one or more of these directories may be writable by standard (non-administrator) users due to incorrect default permissions. If a local attacker places a malicious DLL in such a directory and an administrator subsequently runs the tool, the malicious DLL is loaded into the elevated process and executes with Administrator/SYSTEM privileges. |
| A denial-of-service security issue exists within RSLinx® Classic. The security issue stems from improper handling of a malformed packet. A crafted CIP packet can cause the RSLinx® Classic service to crash, requiring a restart of the service to recover |
| A denial-of-service security issue exists within RSLinx® Classic. A crafted CIP packet with an oversized embedded message request can cause the RSLinx® Classic service to crash, requiring a restart of the service to recover. |
| A denial-of-service security issue exists in the affected Logix platforms listed in the table above. The security issue stems from improper validation of input length during CIP message processing. This can result in a major nonrecoverable fault (MNRF), requiring a power cycle to recover |
| A security issue exists within the Redundancy Module Configuration Tool. The RMConfigTool.exe binary searches directories in the system path for a required DLL, and one or more of these directories may be writable by standard (non-administrator) users due to incorrect default permissions. If a local attacker places a malicious DLL in such a directory and an administrator subsequently runs the tool, the malicious DLL is loaded into the elevated process and executes with Administrator/SYSTEM privileges. |
| A denial-of-service security issue exists within RSLinx® Classic. A crafted CIP packet targeting the Forward Close service can cause the RSLinx® Classic service to crash, requiring a restart of the service to recover. |
| A data exposure vulnerability exists in the affected product. There are hardcoded links in the source code that lead to JSON files that can be reached without authentication. If exploited, a threat actor could view customer data. |
| A vulnerability exists in the affected products that allows a threat actor to create a project and become the administrator for it. If exploited, a threat actor could create, modify, and delete their own project. |
| A security issue exists within FactoryTalk® Historian Machine Edition. An attacker with low-level authentication could exploit this vulnerability to achieve remote code execution on the affected device. |