| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Improper input validation in AMD Crash Defender could allow an attacker to provide the Windows® system process ID to a kernel-mode driver, resulting in an operating system crash, potentially leading to denial of service. |
| Out-of-bounds read vulnerability exists in CX-Programmer included in CX-One CXONE-AL[][]D-V4 Ver. 9.81 or lower. Opening a specially crafted project file may lead to information disclosure and/or the product being crashed. |
| Server receiving a malformed message that uses the hostname in an internal table may cause a stack overflow resulting in possible remote code execution. See Honeywell Security Notification for recommendations on upgrading and versioning.
|
| A vulnerability on Mitel 6800 Series and 6900 Series SIP Phones through 6.3 SP3 HF4, 6900w Series SIP Phone through 6.3.3, and 6970 Conference Unit through 5.1.1 SP8 allows an authenticated attacker to conduct a buffer overflow attack due to insufficient bounds checking and input sanitization. A successful exploit could allow an attacker to gain access to sensitive information, modify system configuration or execute arbitrary commands within the context of the system. |
| Improper input validation in IOMMU could allow a malicious hypervisor to reconfigure IOMMU registers resulting in loss of guest data integrity. |
| ai-client-html is an Aimeos e-commerce HTML client component. Debug information revealed sensitive information from environment variables in error log. This issue has been patched in versions 2024.04.7, 2023.10.15, 2022.10.13 and 2021.10.22. |
| asdcplib (aka AS-DCP Lib) 2.13.1 has a heap-based buffer over-read in ASDCP::TimedText::MXFReader::h__Reader::MD_to_TimedText_TDesc in AS_DCP_TimedText.cpp in libasdcp.so. |
| Panasonic IR Control Hub (IR Blaster) versions 1.17 and earlier may allow an attacker with physical access to load unauthorized firmware onto the device. |
| AutomationDirect C-more EA9 HMI contains a function with bounds checks that can be skipped, which could result in an attacker abusing the function to cause a denial-of-service condition or achieving remote code execution on the affected device. |
| Server receiving a malformed message based on a using the specified key values can cause a heap overflow vulnerability which could lead to an attacker performing remote code execution or causing a failure.
See Honeywell Security Notification for recommendations on upgrading and versioning.
|
| There is a CSV Injection Vulnerability in some HikCentral Master Lite versions. This could allow an attacker to inject executable commands via malicious CSV data. |
| A vulnerability classified as problematic has been found in osrg GoBGP up to 3.37.0. Affected is the function SplitRTR of the file pkg/packet/rtr/rtr.go. The manipulation leads to out-of-bounds read. It is possible to launch the attack remotely. The complexity of an attack is rather high. The exploitability is told to be difficult. The name of the patch is e748f43496d74946d14fed85c776452e47b99d64. It is recommended to apply a patch to fix this issue. |
| Buffer Over-read vulnerability in ABB AC500 V2.This issue affects AC500 V2: through 2.5.2. |
| Certain modem models developed by Askey has a Stack-based Buffer Overflow vulnerability, allowing unauthenticated remote attackers to control the program's execution flow and potentially execute arbitrary code. |
| A security issue exists due to improper handling of CIP Class 32’s request when a module is inhibited on the 5094-IF8 device. It causes the module to enter a fault state with the Module LED flashing red. Upon un-inhibiting, the module returns a connection fault (Code 16#0010), and the module cannot recover without a power cycle. |
| A security issue exists due to improper handling of CIP Class 32’s request when a module is inhibited on the 5094-IY8 device. It causes the module to enter a fault state with the Module LED flashing red. Upon un-inhibiting, the module returns a connection fault (Code 16#0010), and the module cannot recover without a power cycle. |
| Securing externally available CAN wires can easily allow physical access to the CAN bus, allowing possible injection of specially formed CAN messages to control remote start functions of the vehicle. Testing completed on Tesla Model 3 vehicles with software version v11.1 (2023.20.9 ee6de92ddac5). This issue affects Model 3: With software versions from 2023.Xx before 2023.44. |
| openrsync through 0.5.0, as used in OpenBSD through 7.8 and on other platforms, allows a client to cause a server SIGSEGV by specifying a length of zero for block data, because the relationship between p->rem and p->len is not checked. |
| PCSX2 is a free and open-source PlayStation 2 (PS2) emulator. In versions 2.5.377 and below, an unchecked offset and size used in a memcpy operation inside PCSX2's CDVD SCMD 0x91 and SCMD 0x8F handlers allow a specially crafted disc image or ELF to cause an out-of-bounds read from emulator memory. Because the offset and size is controlled through MG header fields, a specially crafted ELF can read data beyond the bounds of mg_buffer and have it reflected back into emulated memory. This issue is fixed in version 2.5.378. |
| An Out-Of-Bounds Read vulnerability affecting the PAR file reading procedure in SOLIDWORKS eDrawings on Release SOLIDWORKS Desktop 2025 could allow an attacker to execute arbitrary code while opening a specially crafted PAR file. |