| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root
This issue affects Iocharger firmware for AC model chargers before version 24120701
Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete
files and services. |
| SAP GUI for Windows may allow the leak of NTML hashes when specific ABAP frontend services are called with UNC paths. For a successful attack, the attacker needs developer authorization in a specific Application Server ABAP to make changes in the code, and the victim needs to execute by using SAP GUI for Windows. This could trigger automatic NTLM authentication, potentially exposing hashed credentials to an attacker. As a result, it has a high impact on the confidentiality. |
| An issue was discovered in Grandstream GXP14XX 1.0.8.9 and GXP16XX 1.0.7.13, allows remote attackers to escalate privileges via incorrect access control using an end-user session-identity token. |
| DYMO LabelWriter Print Server through 2.366 contains a backdoor hard-coded password that could allow an attacker to take control. |
| A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions). Affected devices store user passwords in plaintext without proper protection. This could allow a physical attacker to retrieve them from the embedded storage ICs. |
| calamares-nixos-extensions provides Calamares branding and modules for NixOS, a distribution of GNU/Linux. Users who installed NixOS through the graphical installer who used manual disk partitioning to create a setup where the system was booted via legacy BIOS rather than UEFI; some disk partitions are encrypted; but the partitions containing either `/` or `/boot` are unencrypted; have their LUKS disk encryption key file in plain text either in `/crypto_keyfile.bin`, or in a CPIO archive attached to their NixOS initrd. `nixos-install` is not affected, nor are UEFI installations, nor was the default automatic partitioning configuration on legacy BIOS systems. The problem has been fixed in calamares-nixos-extensions 0.3.17, which was included in NixOS. The current installer images for the NixOS 24.05 and unstable (24.11) channels are unaffected. The fix reached 24.05 at 2024-08-13 20:06:59 UTC, and unstable at 2024-08-15 09:00:20 UTC. Installer images downloaded before those times may be vulnerable. The best solution for affected users is probably to back up their data and do a complete reinstallation. However, the mitigation procedure in GHSA-3rvf-24q2-24ww should work solely for the case where `/` is encrypted but `/boot` is not. If `/` is unencrypted, then the `/crypto_keyfile.bin` file will need to be deleted in addition to the remediation steps in the previous advisory. This issue is a partial regression of CVE-2023-36476 / GHSA-3rvf-24q2-24ww, which was more severe as it applied to the default configuration on BIOS systems. |
| Certain hybrid DVR models ((HBF-09KD and HBF-16NK)) from Hunt Electronic have an Exposure of Sensitive Information vulnerability, allowing unauthenticated remote attackers to directly access a system configuration file and obtain plaintext administrator credentials. |
| Smart-tab Android app installed April 2023 or earlier contains an issue with plaintext storage of a password. If this vulnerability is exploited, an attacker with physical access to the device may retrieve the credential information and spoof the device to access the related external service. |
| An Execution with Unnecessary Privileges vulnerability has been identified in Moxa’s network security appliances and routers. A critical authorization flaw in the API allows an authenticated, low-privileged user to create a new administrator account, including accounts with usernames identical to existing users. In certain scenarios, this vulnerability could allow an attacker to gain full administrative control over the affected device, leading to potential account impersonation. While successful exploitation can severely impact the confidentiality, integrity, and availability of the affected device itself, there is no loss of confidentiality or integrity within any subsequent systems. |
| A vulnerability has been found in FAST/TOOLS and CI Server. The affected products have built-in accounts with no passwords set. Therefore, if the product is operated without a password set by default, an attacker can break into the affected product.
The affected products and versions are as follows:
FAST/TOOLS (Packages: RVSVRN, UNSVRN, HMIWEB, FTEES, HMIMOB) R9.01 to R10.04
CI Server R1.01.00 to R1.03.00 |
| A vulnerability was identified in FNKvision Y215 CCTV Camera 10.194.120.40. Affected by this issue is some unknown functionality of the file /etc/passwd of the component Firmware. Such manipulation leads to hard-coded credentials. Local access is required to approach this attack. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| In International Color Consortium DemoIccMAX before 85ce74e, a logic flaw in CIccTagXmlProfileSequenceId::ParseXml in IccXML/IccLibXML/IccTagXml.cpp results in unconditionally returning false. |
| Command injection in the <redacted> parameter of a <redacted>.exe request leads to remote code execution as the root user.
This issue affects Iocharger firmware for AC models before version 24120701.
Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.
CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). If is a full system compromise, potentially fully compromising confidentiality, integrity and availability of the devicer (VC:H/VI:H/VA:H). A compromised charger can be used to "pivot" onto networks that should otherwise be closed, cause a low confidentiality and interity impact on subsequent systems. (SC:L/SI:L/SA:H). Because this device is an EV charger handing significant amounts of power, we suspect this vulnerability can have a safety impact (S:P). The attack can be automated (AU:Y). |
| A flaw was found in Quay, where Quay's database is stored in plain text in mirror-registry on Jinja's config.yaml file. This issue leaves the possibility of a malicious actor with access to this file to gain access to Quay's Redis instance. |
| CWE-250: Execution with Unnecessary Privileges |
| NetSupport Manager < 14.12.0001 relies on a shared Gateway Key for authentication between Manager/Control, Client, and Connectivity Server components. The key is stored using a reversible encoding scheme. An attacker who obtains access to a deployed client configuration file can decode the stored value to recover the plaintext Gateway Key. Possession of the Gateway Key allows unauthorized access to NetSupport Manager connectivity services and enables remote control of systems managed through the same key. |
| A vulnerability has been identified in SIMATIC BATCH V9.1 (All versions), SIMATIC Information Server 2020 (All versions < V2020 SP2 Update 5), SIMATIC Information Server 2022 (All versions < V2022 SP1 Update 2), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC06), SIMATIC Process Historian 2020 (All versions < V2020 SP2 Update 5), SIMATIC Process Historian 2022 (All versions < V2022 SP1 Update 2), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 5), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 3), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 18), SIMATIC WinCC V8.0 (All versions < V8.0 Update 5). The affected products run their DB server with elevated privileges which could allow an authenticated attacker to execute arbitrary OS commands with administrative privileges. |
| Under certain circumstances the web interface users credentials may be recovered by an authenticated user. |
| User passwords are decrypted and stored on memory before any user logged in. Those decrypted passwords can be retrieved from the coredump file. As for the details of affected product names, model numbers, and versions, refer to the information provided by the respective vendors listed under [References]. |
| An issue in Solar-Log 1000 before v2.8.2 and build 52-23.04.2013 was discovered to store plaintext passwords in the export.html, email.html, and sms.html files -- fixed with 3.0.0-60 11.10.2013 for SL 200, 500, 1000 / not existing for SL 250, 300, 1200, 2000, SL 50 Gateway, SL Base. |