| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Multiple vulnerabilities in the web-based management interface of Cisco Unified Contact Center Express (Unified CCX) could allow an unauthenticated, remote attacker to conduct a cross-site request forgery (CSRF) attack. Cisco Bug IDs: CSCvg70921. |
| Multiple vulnerabilities in the web-based management interface of Cisco Unified Contact Center Express (Unified CCX) could allow an unauthenticated, remote attacker to retrieve a cleartext password. Cisco Bug IDs: CSCvg71040. |
| A vulnerability in the sftunnel functionality of Cisco Firepower Management Center (FMC) Software and Cisco Firepower Threat Defense (FTD) Software could allow an unauthenticated, remote attacker to obtain the device registration hash. The vulnerability is due to insufficient sftunnel negotiation protection during initial device registration. An attacker in a man-in-the-middle position could exploit this vulnerability by intercepting a specific flow of the sftunnel communication between an FMC device and an FTD device. A successful exploit could allow the attacker to decrypt and modify the sftunnel communication between FMC and FTD devices, allowing the attacker to modify configuration data sent from an FMC device to an FTD device or alert data sent from an FTD device to an FMC device. |
| Multiple vulnerabilities in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to conduct a stored cross-site scripting (XSS) attack against a user of the interface of an affected device.
These vulnerabilities are due to insufficient validation of user-supplied input by the web-based management interface. An attacker could exploit these vulnerabilities by inserting crafted input into various data fields in an affected interface. A successful exploit could allow the attacker to execute arbitrary script code in the context of the interface, or access sensitive, browser-based information. In some cases, it is also possible to cause a temporary availability impact to portions of the FMC Dashboard. |
| A vulnerability in the Simple Network Management Protocol (SNMP) access controls for Cisco FirePOWER Software for Adaptive Security Appliance (ASA) FirePOWER module, Cisco Firepower Management Center (FMC) Software, and Cisco Next-Generation Intrusion Prevention System (NGIPS) Software could allow an unauthenticated, remote attacker to perform an SNMP GET request using a default credential.
This vulnerability is due to the presence of a default credential for SNMP version 1 (SNMPv1) and SNMP version 2 (SNMPv2). An attacker could exploit this vulnerability by sending an SNMPv1 or SNMPv2 GET request to an affected device. A successful exploit could allow the attacker to retrieve sensitive information from the device using the default credential.
This attack will only be successful if SNMP is configured, and the attacker can only perform SNMP GET requests; write access using SNMP is not allowed. |
| Multiple vulnerabilities in Cisco Firepower Management Center (FMC) Software and Cisco Firepower User Agent Software could allow an attacker to access a sensitive part of an affected system with a high-privileged account. For more information about these vulnerabilities, see the Details section of this advisory. |
| A vulnerability in the web UI of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to overwrite files on the file system of an affected device. The vulnerability is due to insufficient input validation. An attacker could exploit this vulnerability by uploading a crafted file to the web UI on an affected device. A successful exploit could allow the attacker to overwrite files on the file system of the affected device. |
| A vulnerability in the web UI of Cisco Firepower Management Center (FMC) Software could allow an unauthenticated, remote attacker to write arbitrary entries to the log file on an affected device. The vulnerability is due to insufficient input validation. An attacker could exploit this vulnerability by sending a crafted HTTP request to an affected device. A successful exploit could allow the attacker to send incorrect information to the system log on the affected system. |
| Multiple vulnerabilities in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an unauthenticated, remote attacker to conduct a stored cross-site scripting (XSS) attack against a user of the interface of an affected device. These vulnerabilities are due to insufficient validation of user-supplied input by the web-based management interface. An attacker could exploit these vulnerabilities by inserting crafted input into various data fields in an affected interface. A successful exploit could allow the attacker to execute arbitrary script code in the context of the interface, or access sensitive, browser-based information. In some cases, it is also possible to cause a temporary availability impact to portions of the FMC Dashboard. |
| A vulnerability in the normalization functionality of Cisco Firepower Threat Defense Software, Cisco FirePOWER Services Software for ASA, and Cisco Firepower Management Center Software could allow an unauthenticated, remote attacker to bypass filtering protections. The vulnerability is due to insufficient normalization of a text-based payload. An attacker could exploit this vulnerability by sending traffic that contains specifically obfuscated payloads through an affected device. An exploit could allow the attacker to bypass filtering and deliver malicious payloads to protected systems that would otherwise be blocked. |
| A vulnerability in the file and malware inspection feature of Cisco Firepower Management Center (FMC) Software could allow an unauthenticated, remote attacker to bypass the file and malware inspection policies on an affected system. The vulnerability exists because the affected software insufficiently validates incoming traffic. An attacker could exploit this vulnerability by sending a crafted HTTP request through an affected device. A successful exploit could allow the attacker to bypass the file and malware inspection policies and send malicious traffic through the affected device. |
| A vulnerability in the configuration of the Pluggable Authentication Module (PAM) used in Cisco Firepower Threat Defense (FTD) Software, Cisco Firepower Management Center (FMC) Software, and Cisco FXOS Software could allow an authenticated, remote attacker to cause a denial of service (DoS) condition. The vulnerability is due to improper resource management in the context of user session management. An attacker could exploit this vulnerability by connecting to an affected system and performing many simultaneous successful Secure Shell (SSH) logins. A successful exploit could allow the attacker to exhaust system resources and cause the device to reload, resulting in a DoS condition. To exploit this vulnerability, the attacker needs valid user credentials on the system. |
| A vulnerability in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to execute arbitrary code on the underlying operating system of an affected device. The vulnerability is due to insufficient input validation. An attacker could exploit this vulnerability by sending malicious commands to the web-based management interface of an affected device. A successful exploit could allow the attacker to execute arbitrary code on the underlying operating system of the affected device. |
| A vulnerability in the web UI of the Cisco Firepower Management Center (FMC) could allow an authenticated, remote attacker to execute arbitrary commands on an affected device. The vulnerability is due to insufficient input validation. An attacker could exploit this vulnerability by sending crafted input to the web UI. A successful exploit could allow the attacker to execute arbitrary commands within the affected device. |
| A vulnerability in the web UI of the Cisco Firepower Management Center (FMC) could allow an authenticated, remote attacker to execute arbitrary commands on an affected device. The vulnerability is due to insufficient input validation. An attacker could exploit this vulnerability by sending crafted input to the web UI. A successful exploit could allow the attacker to execute arbitrary commands within the affected device. |
| Multiple vulnerabilities in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to conduct a stored cross-site scripting (XSS) attack against a user of the interface of an affected device.
These vulnerabilities are due to insufficient validation of user-supplied input by the web-based management interface. An attacker could exploit these vulnerabilities by inserting crafted input into various data fields in an affected interface. A successful exploit could allow the attacker to execute arbitrary script code in the context of the interface, or access sensitive, browser-based information. In some cases, it is also possible to cause a temporary availability impact to portions of the FMC Dashboard. |
| A vulnerability in an access control mechanism of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to access services beyond the scope of their authorization. This vulnerability is due to insufficient enforcement of access control in the affected software. An attacker could exploit this vulnerability by directly accessing the internal services of an affected device. A successful exploit could allow the attacker to overwrite policies and impact the configuration and operation of the affected device. |
| Multiple vulnerabilities in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to conduct a cross-site scripting (XSS) attack against a user of the interface. These vulnerabilities are due to insufficient validation of user-supplied input by the web-based management interface. An attacker could exploit these vulnerabilities by persuading a user of the interface to click a crafted link. A successful exploit could allow the attacker to execute arbitrary script code in the context of the interface or access sensitive, browser-based information. |
| Multiple vulnerabilities in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to conduct a cross-site scripting (XSS) attack against a user of the interface. These vulnerabilities are due to insufficient validation of user-supplied input by the web-based management interface. An attacker could exploit these vulnerabilities by persuading a user of the interface to click a crafted link. A successful exploit could allow the attacker to execute arbitrary script code in the context of the interface or access sensitive, browser-based information. |
| A vulnerability in the password change feature of Cisco Firepower Management Center (FMC) software could allow an unauthenticated, remote attacker to determine valid user names on an affected device.
This vulnerability is due to improper authentication of password update responses. An attacker could exploit this vulnerability by forcing a password reset on an affected device. A successful exploit could allow the attacker to determine valid user names in the unauthenticated response to a forced password reset. |