| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A vulnerability exists in the SOAP Web services of the Asset
Suite versions listed below. If successfully exploited, an attacker
could gain unauthorized access to the product and the time window of a possible password attack could be expanded. |
| An attacker could decrypt sensitive data, impersonate legitimate users
or devices, and potentially gain access to network resources for lateral
attacks. |
| The SSH service of PowerStation from HGiga has a Chroot Escape vulnerability, allowing attackers with root privileges to bypass chroot restrictions and access the entire file system. |
| SAP GUI for Windows allows an unauthenticated attacker to exploit insecure obfuscation algorithms used by the GuiXT application to store user credentials. While this issue does not impact the Integrity or Availability of the application, it may have a Low impact on the Confidentiality of data. |
| An attacker with adjacent access, without authentication, can exploit
this vulnerability to retrieve a hard-coded password embedded in
publicly available software. This password can then be used to decrypt
sensitive network traffic, affecting the Cognex device. |
| Use of hard-coded password issue/vulnerability in SS1 Ver.16.0.0.10 and earlier (Media version:16.0.0a and earlier) allows a remote unauthenticated attacker to view arbitrary files with root privileges. |
| Smart Parking Management System from Honding Technology has an Exposure of Sensitive Information vulnerability, allowing unauthenticated remote attackers to access a specific page and obtain plaintext administrator credentials. |
| Multiple wireless router models from Sapido have an Exposure of Sensitive Information vulnerability, allowing unauthenticated remote attackers to directly access a system configuration file and obtain plaintext administrator credentials.
The affected models are out of support; replacing the device is recommended. |
| Certain hybrid DVR models ((HBF-09KD and HBF-16NK)) from Hunt Electronic have an Exposure of Sensitive Information vulnerability, allowing unauthenticated remote attackers to directly access a system configuration file and obtain plaintext administrator credentials. |
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root
This issue affects firmware versions before 24120701.
Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete
files and services.
CVSS clarification: The attack can be executed over any network connection serving the web interface (AV:N). There are no additional measures that need to be circumvented (AC:L) or attack preconditions (AT:N). THe attack is privileged, but the level does not matter (PR:L) and does not require user interaction (UI:N). Attack leads to full system compromised (VC:H/VI:H/VA:H) and compromised devices can be used to "pivot" to other networks that should be unreachable (SC:L/SI:L/SA:H). Because this an EV charger using high power, there is a potential safety impact (S:P). The attack can be automated (AU:Y). |
| A vulnerability was found in Teledyne FLIR FB-Series O and FLIR FH-Series ID 1.3.2.16. It has been classified as problematic. This affects an unknown part. The manipulation leads to use of hard-coded password. It is possible to initiate the attack remotely. The complexity of an attack is rather high. The exploitability is told to be difficult. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| Asseco InfoMedica is a comprehensive solution used to manage both administrative and medical tasks in the healthcare sector. Passwords of all users are stored in a database in an encoded format. An attacker in possession of these encoded passwords is able to decode them by using an algorithm embedded in the client-side part of the software.
This vulnerability has been fixed in versions 4.50.1 and 5.38.0 |
| A vulnerability was found in Belkin F9K1009 and F9K1010 2.00.04/2.00.09 and classified as critical. Affected by this issue is some unknown functionality of the component Web Interface. The manipulation leads to hard-coded credentials. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| This vulnerability exists in Digisol Router (DG-GR1321: Hardware version 3.7L; Firmware version : v3.2.02) due to lack of encryption or hashing in storing of passwords within the router's firmware/ database. An attacker with physical access could exploit this by extracting the firmware and reverse engineer the binary data to access the plaintext passwords on the vulnerable system.
Successful exploitation of this vulnerability could allow the attacker to gain unauthorized access to the targeted system. |
| Execution with Unnecessary Privileges (CWE-250) in Kibana’s Fleet plugin debug route handlers can lead reading index data beyond their direct Elasticsearch RBAC scope via Privilege Abuse (CAPEC-122). This requires an authenticated Kibana user with Fleet sub-feature privileges (such as agents, agent policies, and settings management). |
| IBM Verify Identity Access Container 11.0 through 11.0.2 and IBM Security Verify Access Container 10.0 through 10.0.9.1 and IBM Verify Identity Access 11.0 through 11.0.2 and IBM Security Verify Access 10.0 through 10.0.9.1 could allow a locally authenticated user to escalate their privileges to root due to execution with unnecessary privileges than required. |
| Tenda G1V3.1si V16.01.7.8 Firmware V16.01.7.8 was discovered to contain a hardcoded password vulnerability in /etc_ro/shadow, which allows attackers to log in as root. |
| Tenda i24V3.0si V3.0.0.5 Firmware V3.0.0.5 was discovered to contain a hardcoded password vulnerability in /etc_ro/shadow, which allows attackers to log in as root. |
| The Easy WP SMTP by SendLayer – WordPress SMTP and Email Log Plugin plugin for WordPress is vulnerable to information exposure in all versions up to, and including, 2.3.0. This is due to plugin providing the SMTP password in the SMTP Password field when viewing the settings. This makes it possible for authenticated attackers, with administrative-level access and above, to view the SMTP password for the supplied server. Although this would not be useful for attackers in most cases, if an administrator account becomes compromised this could be useful information to an attacker in a limited environment. |
| The BackWPup plugin for WordPress is vulnerable to Plaintext Storage of Backup Destination Password in all versions up to, and including, 4.0.2. This is due to to the plugin improperly storing backup destination passwords in plaintext. This makes it possible for authenticated attackers, with administrator-level access, to retrieve the password from the password input field in the UI or from the options table where the password is stored. |