| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| When aborting a SFTP connection, MobaXterm before v22.1 sends a hardcoded password to the server. The server treats this as an invalid login attempt which can result in a Denial of Service (DoS) for the user if services like fail2ban are used. |
| PuddingBot is a group management bot. In version 0.0.6-b933652 and prior, the bot token is publicly exposed in main.py, making it accessible to malicious actors. The bot token has been revoked and new version is already running on the server. As of time of publication, the maintainers are planning to update code to reflect this change at a later date. |
| Rundeck is an open source automation service with a web console, command line tools and a WebAPI. Rundeck community and rundeck-enterprise docker images contained a pre-generated SSH keypair. If the id_rsa.pub public key of the keypair was copied to authorized_keys files on remote host, those hosts would allow access to anyone with the exposed private credentials. This misconfiguration only impacts Rundeck Docker instances of PagerDuty® Process Automation On Prem (formerly Rundeck) version 4.0 and earlier, not Debian, RPM or .WAR. Additionally, the id_rsa.pub file would have to be copied from the Docker image filesystem contents without overwriting it and used to configure SSH access on a host. A patch on Rundeck's `main` branch has removed the pre-generated SSH key pair, but it does not remove exposed keys that have been configured. To patch, users must run a script on hosts in their environment to search for exposed keys and rotate them. Two workarounds are available: Do not use any pre-existing public key file from the rundeck docker images to allow SSH access by adding it to authorized_keys files and, if you have copied the public key file included in the docker image, remove it from any authorized_keys files. |
| In Pexip VMR self-service portal before 3, the same SSH host key is used across different customers' installations, which allows authentication bypass. |
| Use of hard-coded credentials vulnerability in multiple Buffalo network devices allows a network-adjacent attacker to alter?configuration settings of the device. The affected products/versions are as follows: WZR-300HP firmware Ver. 2.00 and earlier, WZR-450HP firmware Ver. 2.00 and earlier, WZR-600DHP firmware Ver. 2.00 and earlier, WZR-900DHP firmware Ver. 1.15 and earlier, HW-450HP-ZWE firmware Ver. 2.00 and earlier, WZR-450HP-CWT firmware Ver. 2.00 and earlier, WZR-450HP-UB firmware Ver. 2.00 and earlier, WZR-600DHP2 firmware Ver. 1.15 and earlier, and WZR-D1100H firmware Ver. 2.00 and earlier. |
| FlyteAdmin is the control plane for the data processing platform Flyte. Users who enable the default Flyte’s authorization server without changing the default clientid hashes will be exposed to the public internet. In an effort to make enabling authentication easier for Flyte administrators, the default configuration for Flyte Admin allows access for Flyte Propeller even after turning on authentication via a hardcoded hashed password. This password is also set on the default Flyte Propeller configmap in the various Flyte Helm charts. Users who enable auth but do not override this setting in Flyte Admin’s configuration may unbeknownst to them be allowing public traffic in by way of this default password with attackers effectively impersonating propeller. This only applies to users who have not specified the ExternalAuthorizationServer setting. Usage of an external auth server automatically turns off this default configuration and are not susceptible to this vulnerability. This issue has been addressed in version 1.1.44. Users should manually set the staticClients in the selfAuthServer section of their configuration if they intend to rely on Admin’s internal auth server. Again, users who use an external auth server are automatically protected from this vulnerability. |
| Adobe ColdFusion versions Update 14 (and earlier) and Update 4 (and earlier) are affected by a Use of Hard-coded Credentials vulnerability that could result in application denial-of-service by gaining access to start/stop arbitrary services. Exploitation of this issue does not require user interaction. |
| MegaRAC Default Credentials Vulnerability |
| RTL8111EP-CG/RTL8111FP-CG DASH function has hard-coded password. An unauthenticated physical attacker can use the hard-coded default password during system reboot triggered by other user, to acquire partial system information such as serial number and server information. |
| MegaRAC Default Credentials Vulnerability |
| Databasir is a team-oriented relational database model document management platform. Databasir 1.01 has Use of Hard-coded Cryptographic Key vulnerability. An attacker can use hard coding to generate login credentials of any user and log in to the service background located at different IP addresses. |
| MEDHOST Connex contains hard-coded credentials that are used for customer database access. An attacker with knowledge of the hard-coded credentials and the ability to communicate directly with the database may be able to obtain or modify sensitive patient and financial information. Connex utilizes an IBM i DB2 user account for database access. The account name is HMSCXPDN. Its password is hard-coded in multiple places in the application. Customers do not have the option to change this password. The account has elevated DB2 roles, and can access all objects or database tables on the customer DB2 database. This account can access data through ODBC, FTP, and TELNET. Customers without Connex installed are still vulnerable because the MEDHOST setup program creates this account. |
| Trango Apex <= 2.1.1, ApexLynx < 2.0, ApexOrion < 2.0, ApexPlus <= 3.2.0, Giga <= 2.6.1, GigaLynx < 2.0, GigaOrion < 2.0, GigaPlus <= 3.2.3, GigaPro <= 1.4.1, StrataLink < 3.0, and StrataPro devices have a built-in, hidden root account, with a default password that was once stored in cleartext within a software update package on a Trango FTP server. This account is accessible via SSH and/or TELNET, and grants access to the underlying embedded UNIX OS on the device, allowing full control over it. |
| MEDHOST Connex contains a hard-coded Mirth Connect admin credential that is used for customer Mirth Connect management access. An attacker with knowledge of the hard-coded credential and the ability to communicate directly with the Mirth Connect management console may be able to intercept sensitive patient information. The admin account password is hard-coded as $K8t1ng throughout the application, and is the same across all installations. Customers do not have the option to change the Mirth Connect admin account password. The Mirth Connect admin account is created during the Connex install. The plaintext account password is hard-coded multiple times in the Connex install and update scripts. |
| An issue was discovered on the D-Link DWR-932B router. There is a hardcoded WPS PIN of 28296607. |
| An issue was discovered on the D-Link DWR-932B router. Undocumented TELNET and SSH services provide logins to admin with the password admin and root with the password 1234. |
| D-Link DGS-1100 devices with Rev.B firmware 1.01.018 have a hardcoded SSL private key, which allows man-in-the-middle attackers to spoof devices by hijacking an HTTPS session. |
| The Fedora Nagios package uses "nagiosadmin" as the default password for the "nagiosadmin" administrator account, which makes it easier for remote attackers to obtain access by leveraging knowledge of the credentials. |
| A Use of Hard-Coded Credentials issue was discovered in MRD-305-DIN versions older than 1.7.5.0, and MRD-315, MRD-355, MRD-455 versions older than 1.7.5.0. The device utilizes hard-coded credentials, which could allow for unauthorized local low-privileged access to the device. |
| A hard-coded password of tecn0visi0n for the dlxuser account in TecnoVISION DLX Spot Player4 (all known versions) allows remote attackers to log in via SSH and escalate privileges to root access with the same credentials. |