| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Biometric Shift Employee Management System 3.0 allows remote attackers to bypass intended file-read restrictions via a user=download request with a pathname in the path parameter. |
| A local privilege escalation vulnerability exists in BlueStacks App Player. The BlueStacks App Player installer creates a registry key with weak permissions that allows users to execute arbitrary programs with SYSTEM privileges. |
| MitraStar GPT-2541GNAC (HGU) 1.00(VNJ0)b1 and DSL-100HN-T1 ES_113WJY0b16 devices allow remote authenticated users to obtain root access by specifying /bin/sh as the command to execute. |
| IBM WebSphere Application Server 7.0, 8.0, 8.5, and 9.0 might create files using the default permissions instead of the customized permissions when custom startup scripts are used. A local attacker could exploit this to gain access to files with an unknown impact. IBM X-Force ID: 127153. |
| In Ivanti Service Desk (formerly LANDESK Management Suite) versions between 2016.3 and 2017.3, an Unrestricted Direct Object Reference leads to referencing/updating objects belonging to other users. In other words, a normal user can send requests to a specific URI with the target user's username in an HTTP payload in order to retrieve a key/token and use it to access/update objects belonging to other users. Such objects could be user profiles, tickets, incidents, etc. |
| The SecEmailComposer/EmailComposer application in the Samsung S6 Edge before the October 2015 MR uses weak permissions for the com.samsung.android.email.intent.action.QUICK_REPLY_BACKGROUND service action, which might allow remote attackers with knowledge of the local email address to obtain sensitive information via a crafted application that sends a crafted intent. |
| Huawei FusionServer rack servers RH2288 V3 with software before V100R003C00SPC603, RH2288H V3 with software before V100R003C00SPC503, XH628 V3 with software before V100R003C00SPC602, RH1288 V3 with software before V100R003C00SPC602, RH2288A V2 with software before V100R002C00SPC701, RH1288A V2 with software before V100R002C00SPC502, RH8100 V3 with software before V100R003C00SPC110, CH222 V3 with software before V100R001C00SPC161, CH220 V3 with software before V100R001C00SPC161, and CH121 V3 with software before V100R001C00SPC161 allow remote authenticated operators to change server information by leveraging failure to verify user permissions. |
| Pulp does not remove permissions for named objects upon deletion, which allows authenticated users to gain the privileges of a deleted object via creating an object with the same name. |
| An issue was discovered in Logpoint 7.1 before 7.1.2. The daily executed cron file clean_secbi_old_logs is writable by all users and is executed as root, leading to privilege escalation. |
| Sourcecodester Human Resource Management System 1.0 is vulnerable to Insecure Permissions resulting in privilege escalation. |
| Insecure permission vulnerability in /hrm/leaverequest.php in SourceCodester Human Resource Management System 1.0 allow attackers to approve or reject leave ticket. |
| Sysmac Studio installs executables in a directory with poor permissions. This can allow a locally-authenticated attacker to overwrite files which will result in code execution with privileges of a different user. |
| Apiman 1.5.7 through 2.2.3.Final has insufficient checks for read permissions within the Apiman Manager REST API. The root cause of the issue is the Apiman project's accidental acceptance of a large contribution that was not fully compatible with the security model of Apiman versions before 3.0.0.Final. Because of this, 3.0.0.Final is not affected by the vulnerability. |
| Multiple Mitsubishi Electric Factory Automation engineering software products have a malicious code execution vulnerability. A malicious attacker could use this vulnerability to obtain information, modify information, and cause a denial-of-service condition. |
| Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) is vulnerable to an incorrect default permission in the DIAEnergie application, which may allow an attacker to plant new files (such as DLLs) or replace existing executable files. |
| Successful exploitation of this vulnerability for multiple Mitsubishi Electric Factory Automation Engineering Software Products of various versions could allow an attacker to escalate privilege and execute malicious programs, which could cause a denial-of-service condition, and allow information to be disclosed, tampered with, and/or destroyed. |
| The security descriptor of Measuresoft ScadaPro Server version 6.7 has inconsistent permissions, which could allow a local user with limited privileges to modify the service binary path and start malicious commands with SYSTEM privileges. |
| An issue was discovered in Elspec G5 digital fault recorder versions 1.1.4.15 and before. The shadow file is world readable. |
| WIN-911 2021 R1 and R2 are vulnerable to a permissions misconfiguration that may allow an attacker to locally write files to the Program Announcer directory and elevate permissions whenever the program is executed. |
| WIN-911 2021 R1 and R2 are vulnerable to a permissions misconfiguration that may allow an attacker to locally write files to the program Operator Workspace directory, which holds DLL files and executables. A low-privilege attacker could write a malicious DLL file to the Operator Workspace directory to achieve privilege escalation and the permissions of the user running the program. |