Search
Search Results (86 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2020-8477 | 1 Abb | 1 800xa Information Manager | 2024-11-21 | 8.8 High |
| The installations for ABB System 800xA Information Manager versions 5.1, 6.0 to 6.0.3.2 and 6.1 wrongly contain an auxiliary component. An attacker is able to use this for an XSS-like attack to an authenticated local user, which might lead to execution of arbitrary code. | ||||
| CVE-2020-8320 | 1 Lenovo | 200 Thinkpad 11e, Thinkpad 11e Firmware, Thinkpad 11e Yoga Gen 6 and 197 more | 2024-11-21 | 6.4 Medium |
| An internal shell was included in BIOS image in some ThinkPad models that could allow escalation of privilege. | ||||
| CVE-2020-5763 | 1 Grandstream | 12 Ht801, Ht801 Firmware, Ht802 and 9 more | 2024-11-21 | 8.8 High |
| Grandstream HT800 series firmware version 1.0.17.5 and below contain a backdoor in the SSH service. An authenticated remote attacker can obtain a root shell by correctly answering a challenge prompt. | ||||
| CVE-2020-5756 | 1 Grandstream | 2 Gwn7000, Gwn7000 Firmware | 2024-11-21 | 8.8 High |
| Grandstream GWN7000 firmware version 1.0.9.4 and below allows authenticated remote users to modify the system's crontab via undocumented API. An attacker can use this functionality to execute arbitrary OS commands on the router. | ||||
| CVE-2019-10939 | 1 Siemens | 10 Tim 3v-ie, Tim 3v-ie Advanced, Tim 3v-ie Advanced Firmware and 7 more | 2024-11-21 | 9.8 Critical |
| A vulnerability has been identified in TIM 3V-IE (incl. SIPLUS NET variants) (All versions < V2.8), TIM 3V-IE Advanced (incl. SIPLUS NET variants) (All versions < V2.8), TIM 3V-IE DNP3 (incl. SIPLUS NET variants) (All versions < V3.3), TIM 4R-IE (incl. SIPLUS NET variants) (All versions < V2.8), TIM 4R-IE DNP3 (incl. SIPLUS NET variants) (All versions < V3.3). The affected versions contain an open debug port that is available under certain specific conditions. The vulnerability is only available if the IP address is configured to 192.168.1.2. If available, the debug port could be exploited by an attacker with network access to the device. No user interaction is required to exploit this vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the affected device. At the stage of publishing this security advisory no public exploitation is known. | ||||
| CVE-2018-5454 | 1 Philips | 1 Intellispace Portal | 2024-11-21 | N/A |
| Philips IntelliSpace Portal all versions of 8.0.x, and 7.0.x have a vulnerability where code debugging methods are enabled, which could allow an attacker to remotely execute arbitrary code during runtime. | ||||