CVE-2020-8477 1 Abb 1 800xa Information Manager 2024-11-21 8.8 High
The installations for ABB System 800xA Information Manager versions 5.1, 6.0 to 6.0.3.2 and 6.1 wrongly contain an auxiliary component. An attacker is able to use this for an XSS-like attack to an authenticated local user, which might lead to execution of arbitrary code.
CVE-2020-8320 1 Lenovo 200 Thinkpad 11e, Thinkpad 11e Firmware, Thinkpad 11e Yoga Gen 6 and 197 more 2024-11-21 6.4 Medium
An internal shell was included in BIOS image in some ThinkPad models that could allow escalation of privilege.
CVE-2020-5763 1 Grandstream 12 Ht801, Ht801 Firmware, Ht802 and 9 more 2024-11-21 8.8 High
Grandstream HT800 series firmware version 1.0.17.5 and below contain a backdoor in the SSH service. An authenticated remote attacker can obtain a root shell by correctly answering a challenge prompt.
CVE-2020-5756 1 Grandstream 2 Gwn7000, Gwn7000 Firmware 2024-11-21 8.8 High
Grandstream GWN7000 firmware version 1.0.9.4 and below allows authenticated remote users to modify the system's crontab via undocumented API. An attacker can use this functionality to execute arbitrary OS commands on the router.
CVE-2019-10939 1 Siemens 10 Tim 3v-ie, Tim 3v-ie Advanced, Tim 3v-ie Advanced Firmware and 7 more 2024-11-21 9.8 Critical
A vulnerability has been identified in TIM 3V-IE (incl. SIPLUS NET variants) (All versions < V2.8), TIM 3V-IE Advanced (incl. SIPLUS NET variants) (All versions < V2.8), TIM 3V-IE DNP3 (incl. SIPLUS NET variants) (All versions < V3.3), TIM 4R-IE (incl. SIPLUS NET variants) (All versions < V2.8), TIM 4R-IE DNP3 (incl. SIPLUS NET variants) (All versions < V3.3). The affected versions contain an open debug port that is available under certain specific conditions. The vulnerability is only available if the IP address is configured to 192.168.1.2. If available, the debug port could be exploited by an attacker with network access to the device. No user interaction is required to exploit this vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the affected device. At the stage of publishing this security advisory no public exploitation is known.
CVE-2018-5454 1 Philips 1 Intellispace Portal 2024-11-21 N/A