| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An arbitrary memory write vulnerability was discovered in Supermicro X11DPG-HGX2, X11PDG-QT, X11PDG-OT, and X11PDG-SN motherboards with BIOS firmware before 4.4. |
| An invalid memory access when handling the ProtocolIE_ID field of S1Setup Request messages in Athonet vEPC MME v11.4.0 allows attackers to cause a Denial of Service (DoS) to the cellular network by repeatedly initiating connections and sending a crafted payload. |
| An invalid memory access when handling the ProtocolIE_ID field of E-RAB Modify Request messages in Athonet vEPC MME v11.4.0 allows attackers to cause a Denial of Service (DoS) to the cellular network by repeatedly initiating connections and sending a crafted payload. |
| An issue was discovered on Supermicro BMC firmware in select X11, X12, H12, B12, X13, H13, and B13 motherboards (and CMM6 modules). An unauthenticated user can post crafted data to the interface that triggers a stack buffer overflow, and may lead to arbitrary remote code execution on a BMC. |
| An integer overflow vulnerability in the loading of ExecuTorch models can cause objects to be placed outside their allocated memory area, potentially resulting in code execution or other undesirable effects. This issue affects ExecuTorch prior to commit 0830af8207240df8d7f35b984cdf8bc35d74fa73. |
| An E-RAB Release Command packet containing a malformed NAS PDU will cause the Athonet MME to immediately crash, potentially due to a buffer overflow. |
| A potential buffer overflow vulnerability was reported in PC Manager, Lenovo Browser, and Lenovo App Store that could allow a local attacker to cause a system crash. |
| A malicious client acting as the receiver of an rsync file transfer can trigger an out of bounds read of a heap based buffer, via a negative array index. The
malicious
rsync client requires at least read access to the remote rsync module in order to trigger the issue. |
| For Realtek AmebaD devices, a heap-based buffer overflow was discovered in Ameba-AIoT ameba-arduino-d before version 3.1.9 and ameba-rtos-d before commit c2bfd8216a1cbc19ad2ab5f48f372ecea756d67a on 2025/07/03. In the WLAN driver defragment function, lack of validation of the size of fragmented Wi-Fi frames may lead to a heap-based buffer overflow. |
| Heap Buffer Overflow vulnerability in DumpTS v0.1.0-nightly allows attackers to cause a denial of service via the function PushTSBuf() at /src/PayloadBuf.cpp. |
| Improper input validation in IOMMU could allow a malicious hypervisor to reconfigure IOMMU registers resulting in loss of guest data integrity. |
| An unauthenticated remote attacker can deceive users into performing unintended actions due to improper restriction of rendered UI layers or frames.
|
| util/JSONTokener.java in JSON-lib before 3.1.0 mishandles an unbalanced comment string. |
| XStream is a simple library to serialize objects to XML and back again. This vulnerability may allow a remote attacker to terminate the application with a stack overflow error resulting in a denial of service only by manipulating the processed input stream when XStream is configured to use the BinaryStreamDriver. XStream 1.4.21 has been patched to detect the manipulation in the binary input stream causing the the stack overflow and raises an InputManipulationException instead. Users are advised to upgrade. Users unable to upgrade may catch the StackOverflowError in the client code calling XStream if XStream is configured to use the BinaryStreamDriver. |
| A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.90), SIPROTEC 5 6MD85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD89 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD89 (CP300) V9.6x (All versions < V9.68), SIPROTEC 5 6MU85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7KE85 (CP300) (All versions >= V8.80 < V10.0), SIPROTEC 5 7SA82 (CP150) (All versions < V9.90), SIPROTEC 5 7SA86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SA87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SD82 (CP150) (All versions < V9.90), SIPROTEC 5 7SD86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SD87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SJ86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SK82 (CP150) (All versions < V9.90), SIPROTEC 5 7SK85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SL82 (CP150) (All versions < V9.90), SIPROTEC 5 7SL86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SL87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SS85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7ST85 (CP300) (All versions >= V8.80 < V10.0), SIPROTEC 5 7ST85 (CP300) V9.6x (All versions < V9.68), SIPROTEC 5 7ST86 (CP300) (All versions < V10.0), SIPROTEC 5 7ST86 (CP300) V9.8x (All versions < V9.83), SIPROTEC 5 7SX82 (CP150) (All versions < V9.90), SIPROTEC 5 7SX85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SY82 (CP150) (All versions < V9.90), SIPROTEC 5 7UM85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT82 (CP150) (All versions < V9.90), SIPROTEC 5 7UT85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VE85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VK87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VU85 (CP300) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) V9.8 (All versions < V9.83), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) V9.8 (All versions < V9.83), SIPROTEC 5 Communication Module ETH-BD-2FO (All versions >= V8.80 < V9.90), SIPROTEC 5 Communication Module ETH-BD-2FO V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BD-2FO V9.8 (All versions < V9.83), SIPROTEC 5 Compact 7SX800 (CP050) (All versions >= V9.50 < V9.90). Affected devices do not properly validate SNMP GET requests. This could allow an unauthenticated, remote attacker to retrieve sensitive information of the affected devices with SNMPv2 GET requests using default credentials. |
| Out-of-bounds read for some Intel(R) Graphics Driver software may allow an authenticated user to potentially enable information disclosure via local access. |
| Buffer Overflow vulnerability in Proftpd commit 4017eff8 allows a remote attacker to execute arbitrary code and can cause a Denial of Service (DoS) on the FTP service by sending a maliciously crafted message to the ProFTPD service port. |
| Improper isolation in the Intel(R) Core(TM) Ultra Processor stream cache mechanism may allow an authenticated user to potentially enable escalation of privilege via local access. |
| A stack-based buffer overflow vulnerability exists in ActFax Server version 4.32, specifically in the "Import Users from File" functionality of the client interface. The application fails to properly validate the length of tab-delimited fields in .exp files, leading to unsafe usage of strcpy() during CSV parsing. An attacker can exploit this vulnerability by crafting a malicious .exp file and importing it using the default character set "ECMA-94 / Latin 1 (ISO 8859)". Successful exploitation may result in arbitrary code execution, leading to full system compromise. User interaction is required to trigger the vulnerability. |
| Rollbar.js offers error tracking and logging from Javascript to Rollbar. In versions before 2.26.5 and from 3.0.0-alpha1 to before 3.0.0-beta5, there is a prototype pollution vulnerability in merge(). If application code calls rollbar.configure() with untrusted input, prototype pollution is possible. This issue has been fixed in versions 2.26.5 and 3.0.0-beta5. A workaround involves ensuring that values passed to rollbar.configure() do not contain untrusted input. |