Export limit exceeded: 355998 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Export limit exceeded: 355998 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (6562 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2025-2726 | 2026-04-15 | 8 High | ||
| A vulnerability, which was classified as critical, has been found in H3C Magic NX15, Magic NX30 Pro, Magic NX400, Magic R3010 and Magic BE18000 up to V100R014. Affected by this issue is some unknown functionality of the file /api/esps of the component HTTP POST Request Handler. The manipulation leads to command injection. Access to the local network is required for this attack. The exploit has been disclosed to the public and may be used. It is recommended to upgrade the affected component. | ||||
| CVE-2025-2727 | 2026-04-15 | 8 High | ||
| A vulnerability, which was classified as critical, was found in H3C Magic NX30 Pro up to V100R007. This affects an unknown part of the file /api/wizard/getNetworkStatus of the component HTTP POST Request Handler. The manipulation leads to command injection. Access to the local network is required for this attack to succeed. The exploit has been disclosed to the public and may be used. It is recommended to upgrade the affected component. | ||||
| CVE-2025-2728 | 2026-04-15 | 8 High | ||
| A vulnerability has been found in H3C Magic NX30 Pro and Magic NX400 up to V100R014 and classified as critical. This vulnerability affects unknown code of the file /api/wizard/getNetworkConf. The manipulation leads to command injection. The attack needs to be approached within the local network. It is recommended to upgrade the affected component. | ||||
| CVE-2025-2729 | 2026-04-15 | 8 High | ||
| A vulnerability was found in H3C Magic NX15, Magic NX30 Pro, Magic NX400, Magic R3010 and Magic BE18000 up to V100R014 and classified as critical. This issue affects some unknown processing of the file /api/wizard/networkSetup of the component HTTP POST Request Handler. The manipulation leads to command injection. The attack can only be done within the local network. The exploit has been disclosed to the public and may be used. It is recommended to upgrade the affected component. | ||||
| CVE-2025-2730 | 2026-04-15 | 8 High | ||
| A vulnerability was found in H3C Magic NX15, Magic NX30 Pro, Magic NX400, Magic R3010 and Magic BE18000 up to V100R014. It has been classified as critical. Affected is an unknown function of the file /api/wizard/getssidname of the component HTTP POST Request Handler. The manipulation leads to command injection. The attack can only be initiated within the local network. The exploit has been disclosed to the public and may be used. It is recommended to upgrade the affected component. | ||||
| CVE-2025-2731 | 2026-04-15 | 8 High | ||
| A vulnerability was found in H3C Magic NX15, Magic NX30 Pro, Magic NX400, Magic R3010 and Magic BE18000 up to V100R014. It has been declared as critical. Affected by this vulnerability is an unknown functionality of the file /api/wizard/getDualbandSync of the component HTTP POST Request Handler. The manipulation leads to command injection. The attack needs to be done within the local network. The exploit has been disclosed to the public and may be used. It is recommended to upgrade the affected component. | ||||
| CVE-2025-2732 | 2026-04-15 | 8 High | ||
| A vulnerability was found in H3C Magic NX15, Magic NX30 Pro, Magic NX400, Magic R3010 and Magic BE18000 up to V100R014. It has been rated as critical. Affected by this issue is some unknown functionality of the file /api/wizard/getWifiNeighbour of the component HTTP POST Request Handler. The manipulation leads to command injection. The attack needs to be initiated within the local network. The exploit has been disclosed to the public and may be used. It is recommended to upgrade the affected component. | ||||
| CVE-2025-2733 | 1 Mannaandpoem | 1 Openmanus | 2026-04-15 | 6.3 Medium |
| A vulnerability classified as critical has been found in mannaandpoem OpenManus up to 2025.3.13. This affects an unknown part of the file app/tool/python_execute.py of the component Prompt Handler. The manipulation leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2025-2813 | 1 Phoenixcontact | 2 Axl F Bk Eip, Axl F Bk Pn | 2026-04-15 | 7.5 High |
| An unauthenticated remote attacker can cause a Denial of Service by sending a large number of requests to the http service on port 80. | ||||
| CVE-2025-29509 | 2026-04-15 | 8.8 High | ||
| Jan v0.5.14 and before is vulnerable to remote code execution (RCE) when the user clicks on a rendered link in the conversation, due to opening external website in the app and the exposure of electronAPI, with a lack of filtering of URL when calling shell.openExternal(). | ||||
| CVE-2025-29606 | 2026-04-15 | 4.3 Medium | ||
| py-libp2p before 0.2.3 allows a peer to cause a denial of service (resource consumption) via a large RSA key. | ||||
| CVE-2025-29628 | 2026-04-15 | 9.4 Critical | ||
| A Gardyn Azure IoT Hub connection string is downloaded over an insecure HTTP connection in Gardyn Home Kit firmware before master.619, Home Kit Mobile Application before 2.11.0, and Home Kit Cloud API before 2.12.2026 leaving the string vulnerable to interception and modification through a Man-in-the-Middle attack. This may result in the attacker capturing device credentials or taking control of vulnerable home kits. | ||||
| CVE-2025-2983 | 2026-04-15 | 5.5 Medium | ||
| A vulnerability has been found in Legrand SMS PowerView 1.x and classified as critical. Affected by this vulnerability is an unknown functionality. The manipulation of the argument redirect leads to os command injection. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2025-32380 | 2026-04-15 | 7.5 High | ||
| The Apollo Router Core is a configurable, high-performance graph router written in Rust to run a federated supergraph that uses Apollo Federation 2. A vulnerability in Apollo Router's usage of Apollo Compiler allowed queries with deeply nested and reused named fragments to be prohibitively expensive to validate. This could lead to excessive resource consumption and denial of service. Apollo Router's usage of Apollo Compiler has been updated so that validation logic processes each named fragment only once, preventing redundant traversal. This has been remediated in apollo-router versions 1.61.2 and 2.1.1. | ||||
| CVE-2025-37102 | 2026-04-15 | 7.2 High | ||
| An authenticated command injection vulnerability exists in the Command line interface of HPE Networking Instant On Access Points. A successful exploitation could allow a remote attacker with elevated privileges to execute arbitrary commands on the underlying operating system as a highly privileged user. | ||||
| CVE-2025-37146 | 1 Hpe | 1 Arubaos | 2026-04-15 | 7.2 High |
| A vulnerability in the web-based management interface of network access point configuration services could allow an authenticated remote attacker to perform remote command execution. Successful exploitation could allow an attacker to execute arbitrary commands on the underlying operating system. | ||||
| CVE-2023-32255 | 1 Redhat | 1 Enterprise Linux | 2026-04-15 | 5.3 Medium |
| A flaw was found in the Linux kernel's ksmbd component. A memory leak can occur if a client sends a session setup request with an unknown NTLMSSP message type, potentially leading to resource exhaustion. | ||||
| CVE-2025-37166 | 1 Hpe | 1 Aruba Instant On | 2026-04-15 | 7.5 High |
| A vulnerability affecting HPE Networking Instant On Access Points has been identified where a device processing a specially crafted packet could enter a non-responsive state, in some cases requiring a hard reset to re-establish services. A malicious actor could leverage this vulnerability to conduct a Denial-of-Service attack on a target network. | ||||
| CVE-2025-40570 | 1 Siemens | 1 Siprotec 5 | 2026-04-15 | 2.4 Low |
| A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V10.0), SIPROTEC 5 6MD85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 6MD86 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 6MD89 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 6MU85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7KE85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SA82 (CP150) (All versions < V10.0), SIPROTEC 5 7SA86 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SA87 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SD82 (CP150) (All versions < V10.0), SIPROTEC 5 7SD86 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SD87 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SJ81 (CP150) (All versions < V10.0), SIPROTEC 5 7SJ82 (CP150) (All versions < V10.0), SIPROTEC 5 7SJ85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SJ86 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SK82 (CP150) (All versions < V10.0), SIPROTEC 5 7SK85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SL82 (CP150) (All versions < V10.0), SIPROTEC 5 7SL86 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SL87 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7SS85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7ST85 (CP300) (All versions < V10.0), SIPROTEC 5 7ST86 (CP300) (All versions < V10.0), SIPROTEC 5 7SX82 (CP150) (All versions < V10.0), SIPROTEC 5 7SX85 (CP300) (All versions < V10.0), SIPROTEC 5 7SY82 (CP150) (All versions < V10.0), SIPROTEC 5 7UM85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7UT82 (CP150) (All versions < V10.0), SIPROTEC 5 7UT85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7UT86 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7UT87 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7VE85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7VK87 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 7VU85 (CP300) (All versions < V10.0), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V10.0). Affected devices do not properly limit the bandwidth for incoming network packets over their local USB port. This could allow an attacker with physical access to send specially crafted packets with high bandwidth to the affected devices thus forcing them to exhaust their memory and stop responding to any network traffic via the local USB port. Affected devices reset themselves automatically after a successful attack. The protection function is not affected of this vulnerability. | ||||
| CVE-2025-41451 | 1 Danfoss | 1 Ak-sm8xxa Series | 2026-04-15 | N/A |
| Improper neutralization of alarm-to-mail configuration fields used in an OS shell Command ('Command Injection') in Danfoss AK-SM8xxA Series prior to version 4.3.1, leading to a potential post-authenticated remote code execution on an attacked system. | ||||