CVE Vendors Products Updated CVSS v3.1
CVE-2024-49397 1 Elvaco 1 Cme3100 Firmware 2026-04-15 N/A
The affected product is vulnerable to a cross-site scripting attack which may allow an attacker to bypass authentication and takeover admin accounts.
CVE-2024-4826 2026-04-15 9.8 Critical
SQL injection vulnerability in Simple PHP Shopping Cart affecting version 0.9. This vulnerability could allow an attacker to retrieve all the information stored in the database by sending a specially crafted SQL query, due to the lack of proper sanitisation of the category_id parameter in the category.php file.
CVE-2024-47138 1 Myscada 2 Mypro Manager, Mypro Runtime 2026-04-15 9.8 Critical
The administrative interface listens by default on all interfaces on a TCP port and does not require authentication when being accessed.
CVE-2025-34030 2026-04-15 N/A
An OS command injection vulnerability exists in sar2html version 3.2.2 and prior via the plot parameter in index.php. The application fails to sanitize user-supplied input before using it in a system-level context. Remote, unauthenticated attackers can inject shell commands by appending them to the plot parameter (e.g., ?plot=;id) in a crafted GET request. The output of the command is displayed in the application's interface after interacting with the host selection UI. Successful exploitation leads to arbitrary command execution on the underlying system. Exploitation evidence was observed by the Shadowserver Foundation on 2025-02-04 UTC.
CVE-2025-34153 1 Hyland 1 Onbase 2026-04-15 N/A
Hyland OnBase versions prior to 17.0.2.87 (other versions may be affected) are vulnerable to unauthenticated remote code execution via insecure deserialization on the .NET Remoting TCP channel. The service registers a listener on port 6031 with the URI endpoint TimerServer, implemented in Hyland.Core.Timers.dll. This endpoint deserializes untrusted input using the .NET BinaryFormatter, allowing attackers to execute arbitrary code under the context of NT AUTHORITY\SYSTEM.
CVE-2009-20007 1 Talkative 1 Irc 2026-04-15 N/A
Talkative IRC v0.4.4.16 is vulnerable to a stack-based buffer overflow when processing specially crafted response strings sent to a connected client. An attacker can exploit this flaw by sending an overly long message that overflows a fixed-length buffer, potentially leading to arbitrary code execution in the context of the vulnerable process. This vulnerability is exploitable remotely and does not require authentication.
CVE-2024-43651 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC models before version 241207101 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network connection serving the web interface is vulnerable (AV:N) and there are no additional measures to circumvent (AC:L) nor does the attack require special conditions to be present (AT:N). The attack requires authentication, but the level does not matter (PR:L), nor is user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H) and a compromised device can be used to potentially "pivot" into a network that should nopt be reachable (SC:L/SI:L/SA:H). Because this is an EV charger handing significant power, there is a potential safety impact (S:P). THe attack can be autometed (AU:Y).
CVE-2024-43653 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability  allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43654 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects all Iocharger AC EV charger models on a firmware version before 25010801. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-41798 1 Siemens 1 Sentron Pac3200 2026-04-15 9.8 Critical
A vulnerability has been identified in SENTRON 7KM PAC3200 (All versions). Affected devices only provide a 4-digit PIN to protect from administrative access via Modbus TCP interface. Attackers with access to the Modbus TCP interface could easily bypass this protection by brute-force attacks or by sniffing the Modbus clear text communication.
CVE-2025-58438 1 Microsoft 1 Windows 2026-04-15 N/A
internetarchive is a Python and Command-Line Interface to Archive.org In versions 5.5.0 and below, there is a directory traversal (path traversal) vulnerability in the File.download() method of the internetarchive library. The file.download() method does not properly sanitize user-supplied filenames or validate the final download path. A maliciously crafted filename could contain path traversal sequences (e.g., ../../../../windows/system32/file.txt) or illegal characters that, when processed, would cause the file to be written outside of the intended target directory. An attacker could potentially overwrite critical system files or application configuration files, leading to a denial of service, privilege escalation, or remote code execution, depending on the context in which the library is used. The vulnerability is particularly critical for users on Windows systems, but all operating systems are affected. This issue is fixed in version 5.5.1.
CVE-2025-32020 2026-04-15 N/A
The crud-query-parser library parses query parameters from HTTP requests and converts them to database queries. Improper neutralization of the order/sort parameter in the TypeORM adapter, which allows SQL injection. You are impacted by this vulnerability if you are using the TypeORM adapter, ordering is enabled and you have not set-up a property filter. This vulnerability is fixed in 0.1.0.
CVE-2024-33499 1 Siemens 1 Simatic Rtls Locating Manager 2026-04-15 9.1 Critical
A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). The affected application assigns incorrect permissions to a user management component. This could allow a privileged attacker to escalate their privileges from the Administrators group to the Systemadministrator group.
CVE-2025-53695 1 Johnsoncontrols 1 Istar Ultra 2026-04-15 N/A
OS Command Injection in iSTAR Ultra products web application allows an authenticated attacker to gain even more privileged access ('root' user) to the device firmware.
CVE-2024-30407 2026-04-15 8.1 High
The Use of a Hard-coded Cryptographic Key vulnerability in Juniper Networks Juniper Cloud Native Router (JCNR) and containerized routing Protocol Deamon (cRPD) products allows an attacker to perform Person-in-the-Middle (PitM) attacks which results in complete compromise of the container. Due to hardcoded SSH host keys being present on the container, a PitM attacker can intercept SSH traffic without being detected.  This issue affects Juniper Networks JCNR: * All versions before 23.4. This issue affects Juniper Networks cRPD: * All versions before 23.4R1.
CVE-2024-30209 1 Siemens 1 Simatic Rtls Locating Manager 2026-04-15 9.6 Critical
A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). Affected systems transmit client-side resources without proper cryptographic protection. This could allow an attacker to eavesdrop on and modify resources in transit. A successful exploit requires an attacker to be in the network path between the RTLS Locating Manager server and a client (MitM).
CVE-2024-30207 1 Siemens 1 Simatic Rtls Locating Manager 2026-04-15 10 Critical
A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). The affected systems use symmetric cryptography with a hard-coded key to protect the communication between client and server. This could allow an unauthenticated remote attacker to compromise confidentiality and integrity of the communication and, subsequently, availability of the system. A successful exploit requires the attacker to gain knowledge of the hard-coded key and to be able to intercept the communication between client and server on the network.
CVE-2011-10017 1 Snort 1 Snort 2026-04-15 N/A
Snort Report versions < 1.3.2 contains a remote command execution vulnerability in the nmap.php and nbtscan.php scripts. These scripts fail to properly sanitize user input passed via the target GET parameter, allowing attackers to inject arbitrary shell commands. Exploitation requires no authentication and can result in full compromise of the underlying system.
CVE-2011-10016 2026-04-15 N/A
Real Networks Netzip Classic version 7.5.1.86 is vulnerable to a stack-based buffer overflow when parsing a specially crafted ZIP archive. The vulnerability is triggered when the application attempts to process a file name within the archive that exceeds the expected buffer size. Exploitation allows arbitrary code execution under the context of the victim user when the ZIP file is opened.
CVE-2011-10015 2026-04-15 N/A
Cytel Studio version 9.0 and earlier is vulnerable to a stack-based buffer overflow triggered by parsing a malformed .CY3 file. The vulnerability occurs when the application copies user-controlled strings into a fixed-size stack buffer (256 bytes) without proper bounds checking. Exploitation allows arbitrary code execution when the crafted file is opened.