| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| IBM BigFix Compliance (TEMA SUAv1 SCA SCM) uses an inadequate account lockout setting that could allow a remote attacker to brute force account credentials. IBM X-Force ID: 123672. |
| When the device is configured to perform account lockout with a defined period of time, any unauthenticated user attempting to log in as root with an incorrect password can trigger a lockout of the root account. When an SRX Series device is in cluster mode, and a cluster sync or failover operation occurs, then there will be errors associated with synch or failover while the root account is locked out. Administrators can confirm if the root account is locked out via the following command root@device> show system login lockout user root User Lockout start Lockout end root 1995-01-01 01:00:01 PDT 1995-11-01 01:31:01 PDT Affected releases are Juniper Networks Junos OS 12.1X46 prior to 12.1X46-D65 on SRX series; 12.3X48 prior to 12.3X48-D45 on SRX series; 15.1X49 prior to 15.1X49-D75 on SRX series. |
| In all Android releases from CAF using the Linux kernel, the Hypervisor API could be misused to bypass authentication. |
| An issue was discovered in Logpoint before 7.5.0. An endpoint used by Distributed Logpoint Setup was exposed, allowing unauthenticated attackers to bypass CSRF protections and authentication. |
| Aethon TUG Home Base Server versions prior to version 24 are affected by un unauthenticated attacker who can freely access hashed user credentials. |
| A specially crafted script could cause the DeltaV Distributed Control System Controllers (All Versions) to restart and cause a denial-of-service condition. |
| An attacker can decrypt the Ovarro TBox login password by communication capture and brute force attacks. |
| A vulnerability was found in CodeAstro House Rental Management System 1.0. It has been rated as problematic. Affected by this issue is some unknown functionality of the file booking.php/owner.php/tenant.php. The manipulation leads to missing authentication. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-255392. |
| AVEVA System Platform versions 2017 through 2020 R2 P01 does not perform any authentication for functionality that requires a provable user identity. |
|
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior lacks authentication for a function that changes group privileges. An attacker could use this to create a denial-of-service state or escalate their own privileges.
|
| Fresenius Kabi Agilia SP MC WiFi vD25 and prior has a default configuration page accessible without authentication. An attacker may use this functionality to change the exposed configuration values such as network settings. |
| Emerson OpenEnterprise versions through 3.3.4 may allow an attacker to run an arbitrary commands with system privileges or perform remote code execution via a specific communication service. |
| Power Line Communications PLC4TRUCKS J2497 trailer brake controllers implement diagnostic functions which can be invoked by replaying J2497 messages. There is no authentication or authorization for these functions. |
| Axeda agent (All versions) and Axeda Desktop Server for Windows (All versions) may allow an attacker to send certain commands to a specific port without authentication. Successful exploitation of this vulnerability could allow a remote unauthenticated attacker to obtain full file-system access and remote code execution. |
| When connecting to a certain port Axeda agent (All versions) and Axeda Desktop Server for Windows (All versions) may allow an attacker to send a certain command to a specific port without authentication. Successful exploitation of this vulnerability could allow a remote unauthenticated attacker to shut down a specific service. |
| When connecting to a certain port Axeda agent (All versions) and Axeda Desktop Server for Windows (All versions) may allow an attacker to send certain XML messages to a specific port without proper authentication. Successful exploitation of this vulnerability could allow a remote unauthenticated attacker to read and modify the affected product’s configuration. |
| The software does not perform any authentication for critical system functionality. |
| Sensitive information can be obtained through the handling of serialized data. The issue results from the lack of proper authentication required to query the server |
| There is no limit to the number of attempts to authenticate for the local configuration pages for the Hills ComNav Version 3002-19 interface, which allows local attackers to brute-force credentials. |
| LRM does not implement authentication or authorization by default. A malicious actor can inject, replay, modify, and/or intercept sensitive data. |