| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Trilium Notes is an open-source, cross-platform hierarchical note taking application with focus on building large personal knowledge bases. In versions below 0.97.0, a brute-force protection bypass in the initial sync seed retrieval endpoint allows unauthenticated attackers to guess the login password without triggering rate limiting. Trilium is a single-user app without a username requirement, and brute-force protection bypass makes exploitation much more feasible. Multiple features provided by Trilium (e.g. MFA, share notes, custom request handler) indicate that Trilium can be exposed to the internet. This is fixed in version 0.97.0. |
| Due to missing authentication on a critical function of the devices an unauthenticated remote attacker can execute arbitrary commands, potentially enabling unauthorized upload or download of configuration files and leading to full system compromise. |
| On the exos 9300 server, a SOAP API is reachable on port 8002. This API does not require any authentication prior to sending requests. Therefore, network access to the exos server allows e.g. the creation of arbitrary access log events as well as querying the 2FA PINs associated with the enrolled chip cards. |
| The exos 9300 application can be used to configure Access Managers (e.g. 92xx, 9230 and 9290). The configuration is done in a graphical user interface on the dormakaba exos server. As soon as the save button is clicked in exos 9300, the whole configuration is sent to the selected Access Manager via SOAP. The SOAP request is sent without any prior authentication or authorization by default. Though authentication and authorization can be configured using IPsec for 92xx-K5 devices and mTLS for 92xx-K7 devices, it is not enabled by default and must therefore be activated with additional steps.
This insecure default allows an attacker with network level access to completely control the whole environment. An attacker is for example easily able to conduct the following tasks without prior authentication:
- Re-configure Access Managers (e.g. remove alarming system requirements)
- Freely re-configure the inputs and outputs
- Open all connected doors permanently
- Open all doors for a defined time interval
- Change the admin password
- and many more
Network level access can be gained due to an insufficient network segmentation as well as missing LAN firewalls. Devices with an insecure configuration have been identified to be directly exposed to the internet. |
| A vulnerability was found in rowboatlabs rowboat up to 8096eaf63b5a0732edd8f812bee05b78e214ee97. It has been rated as critical. Affected by this issue is the function PUT of the file apps/rowboat/app/api/uploads/[fileId]/route.ts of the component Session Handler. The manipulation of the argument params leads to missing authentication. The attack may be launched remotely. Continious delivery with rolling releases is used by this product. Therefore, no version details of affected nor updated releases are available. It is expected that this issue will be fixed in the near future. |
| The airPASS from NetVision Information has a Missing Authentication vulnerability, allowing unauthenticated remote attackers to access the specific administrative functionality to retrieve * all accounts and passwords. |
| COMMAX Smart Home System allows an unauthenticated attacker to change configuration and cause denial-of-service through the setconf endpoint. Attackers can trigger a denial-of-service scenario by sending a malformed request to the setconf endpoint. |
| A vulnerability has been discovered in AC Smart II where passwords can be changed without authorization. This page contains a hidden form for resetting the administrator password. The attacker can manipulate the page using developer tools to display and use the form. This form allows you to change the administrator password without verifying login status or user permissions. |
| Ant Media Server Community Edition in a default configuration is vulnerable to an improper HTTP header based authorization, leading to a possible use of non-administrative API calls reserved only for authorized users.
All versions up to 2.9.0 (tested) and possibly newer ones are believed to be vulnerable as the vendor has not confirmed releasing a patch. |
| Improper resource management in firmware of some Solidigm DC Products may allow an attacker with local or physical access to gain un-authorized access to a locked storage device. |
| A vulnerability was found in Papendorf SOL Connect Center 3.3.0.0 and classified as problematic. Affected by this issue is some unknown functionality of the component Web Interface. The manipulation leads to missing authentication. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| Burk Technology ARC Solo's password change mechanism can be utilized without proper
authentication procedures, allowing an attacker to take over the device.
A password change request can be sent directly to the device's HTTP
endpoint without providing valid credentials. The system does not
enforce proper authentication or session validation, allowing the
password change to proceed without verifying the request's legitimacy. |
| The Amp’ed RF BT-AP 111 Bluetooth access point's HTTP admin interface does not have an authentication feature, allowing unauthorized access to anyone with network access. |
| Nedap Librix Ecoreader
is missing authentication for critical functions that could allow an
unauthenticated attacker to potentially execute malicious code. |
| An Incorrect Implementation of Authentication Algorithm and Exposure of Data Element to Wrong Ses-sion vulnerability in the session handling used in B&R APROL <4.4-00P5 may allow an authenticated network attacker to take over a currently active user session without login credentials. |
| Yealink RPS before 2025-06-04 lacks SN verification attempt limits, enabling brute-force enumeration (last five digits). |
| An attacker could modify or disable settings, disrupt fuel monitoring
and supply chain operations, leading to disabling of ATG monitoring.
This would result in potential safety hazards in fuel storage and
transportation. |
| Aviatrix Controller versions prior to 7.1.4208, 7.2.5090, and 8.0.0 do not enforce rate limiting on password reset attempts, allowing adversaries to brute force guess the 6-digit password reset PIN |
| An issue in Fermax Asia Pacific Pte Ltd com.fermax.vida 2.4.6 allows a remote attacker to obtain sensitve information via the firmware update process. |
| An issue in Plug n Play Camera com.ezset.delaney 1.2.0 allows a remote attacker to obtain sensitive information via the firmware update process. |