Export limit exceeded: 46120 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (46120 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2022-26367 | 1 Intel | 2 Xmm 7560, Xmm 7560 Firmware | 2025-02-05 | 6 Medium |
| Improper buffer restrictions in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via local access. | ||||
| CVE-2022-26045 | 1 Intel | 2 Xmm 7560, Xmm 7560 Firmware | 2025-02-05 | 3.3 Low |
| Improper buffer restrictions in some Intel(R) XMM(TM) 7560 Modem software before version M2_7560_R_01.2146.00 may allow a privileged user to potentially enable escalation of privilege via physical access. | ||||
| CVE-2021-0876 | 1 Google | 1 Android | 2025-02-05 | 7.8 High |
| In PVRSRVBridgePhysmemNewRamBackedLockedPMR of the PowerVR kernel driver, a missing size check means there is a possible integer overflow that could allow out-of-bounds heap access. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android SoCAndroid ID: A-270400229 | ||||
| CVE-2021-0875 | 1 Google | 1 Android | 2025-02-05 | 7.8 High |
| In PVRSRVBridgeChangeSparseMem of the PowerVR kernel driver, a missing size check means there is a possible integer overflow that could allow out-of-bounds heap access. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android SoCAndroid ID: A-270400061 | ||||
| CVE-2021-0874 | 1 Google | 1 Android | 2025-02-05 | 7.8 High |
| In PVRSRVBridgeDevicememHistorySparseChange of the PowerVR kernel driver, a missing size check means there is a possible integer overflow that could allow out-of-bounds heap access. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android SoCAndroid ID: A-270399633 | ||||
| CVE-2021-0873 | 1 Google | 1 Android | 2025-02-05 | 7.8 High |
| In PVRSRVBridgeRGXKickRS of the PowerVR kernel driver, a missing size check means there is a possible integer overflow that could allow out-of-bounds heap access. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android SoCAndroid ID: A-270392711 | ||||
| CVE-2021-0872 | 1 Google | 1 Android | 2025-02-05 | 7.8 High |
| In PVRSRVBridgeRGXKickVRDM of the PowerVR kernel driver, a missing size check means there is a possible integer overflow that could allow out-of-bounds heap access. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android SoCAndroid ID: A-270401229 | ||||
| CVE-2023-2017 | 1 Shopware | 1 Shopware | 2025-02-05 | 8.8 High |
| Server-side Template Injection (SSTI) in Shopware 6 (<= v6.4.20.0, v6.5.0.0-rc1 <= v6.5.0.0-rc4), affecting both shopware/core and shopware/platform GitHub repositories, allows remote attackers with access to a Twig environment without the Sandbox extension to bypass the validation checks in `Shopware\Core\Framework\Adapter\Twig\SecurityExtension` and call any arbitrary PHP function and thus execute arbitrary code/commands via usage of fully-qualified names, supplied as array of strings, when referencing callables. Users are advised to upgrade to v6.4.20.1 to resolve this issue. This is a bypass of CVE-2023-22731. | ||||
| CVE-2021-23165 | 1 Htmldoc Project | 1 Htmldoc | 2025-02-05 | 9.8 Critical |
| A flaw was found in htmldoc before v1.9.12. Heap buffer overflow in pspdf_prepare_outpages(), in ps-pdf.cxx may lead to execute arbitrary code and denial of service. | ||||
| CVE-2022-32522 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2025-02-05 | 9.8 Critical |
| A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted mathematically reduced data request messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170) | ||||
| CVE-2022-32523 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2025-02-05 | 9.8 Critical |
| A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted online data request messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170) | ||||
| CVE-2022-32524 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2025-02-05 | 9.8 Critical |
| A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted time reduced data messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170) | ||||
| CVE-2022-32525 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2025-02-05 | 9.8 Critical |
| A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted alarm data messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170) | ||||
| CVE-2022-32526 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2025-02-05 | 9.8 Critical |
| A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted setting value messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170) | ||||
| CVE-2022-32527 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2025-02-05 | 9.8 Critical |
| A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted alarm cache data messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170) | ||||
| CVE-2022-32529 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2025-02-05 | 9.8 Critical |
| A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted log data request messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170) | ||||
| CVE-2022-24324 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2025-02-05 | 9.8 Critical |
| A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22073) | ||||
| CVE-2022-2329 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2025-02-05 | 9.8 Critical |
| A CWE-190: Integer Overflow or Wraparound vulnerability exists that could cause heap-based buffer overflow, leading to denial of service and potentially remote code execution when an attacker sends multiple specially crafted messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22073) | ||||
| CVE-2022-32512 | 1 Schneider-electric | 1 Canbrass | 2025-02-05 | 5.3 Medium |
| A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause remote code execution when a command which exploits this vulnerability is utilized. Affected Products: CanBRASS (Versions prior to V7.5.1) | ||||
| CVE-2022-32517 | 1 Schneider-electric | 2 Conext Combox, Conext Combox Firmware | 2025-02-05 | 6.5 Medium |
| A CWE-1021: Improper Restriction of Rendered UI Layers or Frames vulnerability exists that could cause an adversary to trick the interface user/admin into interacting with the application in an unintended way when the product does not implement restrictions on the ability to render within frames on external addresses. Affected Products: Conextâ„¢ ComBox (All Versions) | ||||