Export limit exceeded: 356855 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (356855 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2025-40944 | 1 Siemens | 15 Simatic Et 200al Im 157-1 Pn, Simatic Et 200mp Im 155-5 Pn Hf, Simatic Et 200sp Im 155-6 Mf Hf and 12 more | 2026-06-09 | 7.5 High |
| A vulnerability has been identified in SIMATIC ET 200AL IM 157-1 PN (6ES7157-1AB00-0AB0) (All versions), SIMATIC ET 200MP IM 155-5 PN HF (6ES7155-5AA00-0AC0) (All versions >= V4.2.0), SIMATIC ET 200SP IM 155-6 MF HF (6ES7155-6MU00-0CN0) (All versions), SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants) (All versions < V1.3), SIMATIC ET 200SP IM 155-6 PN R1 (6ES7155-6AU00-0HM0) (All versions < V6.0.1), SIMATIC ET 200SP IM 155-6 PN/2 HF (6ES7155-6AU01-0CN0) (All versions >= V4.2.0 < V4.2.5), SIMATIC ET 200SP IM 155-6 PN/3 HF (6ES7155-6AU30-0CN0) (All versions < V4.2.2), SIMATIC PN/MF Coupler (6ES7158-3MU10-0XA0) (All versions), SIMATIC PN/PN Coupler (6ES7158-3AD10-0XA0) (All versions < V6.0.0), SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-2AC0) (All versions >= V4.2.0), SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-7AC0) (All versions >= V4.2.0), SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL (6AG2155-5AA00-1AC0) (All versions >= V4.2.0), SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-2CN0) (All versions >= V4.2.0 < V4.2.5), SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-7CN0) (All versions >= V4.2.0 < V4.2.5), SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL (6AG2155-6AU01-1CN0) (All versions >= V4.2.0 < V4.2.5), SIPLUS ET 200SP IM 155-6 PN HF TX RAIL (6AG2155-6AU01-4CN0) (All versions >= V4.2.0 < V4.2.5), SIPLUS NET PN/PN Coupler (6AG2158-3AD10-4XA0) (All versions < V6.0.0). Affected devices do not properly handle S7 protocol session disconnect requests. When receiving a valid S7 protocol Disconnect Request (COTP DR TPDU) on TCP port 102, the devices enter an improper session state. This could allow an attacker to cause the device to become unresponsive, leading to a denial-of-service condition that requires a power cycle to restore normal operation. | ||||
| CVE-2025-40936 | 1 Siemens | 1 Ps Iges Parasolid Translator Component | 2026-06-09 | 7.8 High |
| A vulnerability has been identified in PS/IGES Parasolid Translator Component (All versions < V29.0.258), Simcenter Femap (All versions < V2512.0003), Solid Edge (All versions < V226.00 Update 03). The affected applications contains an out of bounds read vulnerability while parsing specially crafted IGS files. This could allow an attacker to crash the application or execute code in the context of the current process. (ZDI-CAN-26755) | ||||
| CVE-2025-40798 | 1 Siemens | 3 Simatic, Simatic Pcs Neo, User Management Component | 2026-06-09 | 7.5 High |
| A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATIC PCS neo V6.0 (All versions < V6.0 SP1 Update 1), User Management Component (UMC) (All versions < V2.15.1.3). Affected products contain a out-of-bounds read vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to cause a denial of service condition. | ||||
| CVE-2025-40797 | 1 Siemens | 3 Simatic, Simatic Pcs Neo, User Management Component | 2026-06-09 | 7.5 High |
| A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATIC PCS neo V6.0 (All versions < V6.0 SP1 Update 1), User Management Component (UMC) (All versions < V2.15.1.3). Affected products contain a out-of-bounds read vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to cause a denial of service condition. | ||||
| CVE-2025-40796 | 1 Siemens | 3 Simatic, Simatic Pcs Neo, User Management Component | 2026-06-09 | 7.5 High |
| A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATIC PCS neo V6.0 (All versions < V6.0 SP1 Update 1), User Management Component (UMC) (All versions < V2.15.1.3). Affected products contain a out-of-bounds read vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to cause a denial of service condition. | ||||
| CVE-2025-40795 | 1 Siemens | 3 Simatic, Simatic Pcs Neo, User Management Component | 2026-06-09 | 9.8 Critical |
| A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATIC PCS neo V6.0 (All versions < V6.0 SP1 Update 1), User Management Component (UMC) (All versions < V2.15.1.3). Affected products contain a stack-based buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to execute arbitrary code or to cause a denial of service condition. | ||||
| CVE-2024-54678 | 1 Siemens | 13 Simatic Pcs Neo, Simatic S7-plcsim, Simatic Step 7 and 10 more | 2026-06-09 | 8.2 High |
| A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATIC PCS neo V6.0 (All versions < V6.0 SP1 Update 1), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC STEP 7 V20 (All versions < V20 Update 4), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMATIC WinCC V20 (All versions < V20 Update 4), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOCODE ES V20 (All versions), SIMOTION SCOUT TIA V5.4 (All versions), SIMOTION SCOUT TIA V5.5 (All versions), SIMOTION SCOUT TIA V5.6 (All versions < V5.6 SP1 HF7), SIMOTION SCOUT TIA V5.7 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SINAMICS Startdrive V20 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Safety ES V20 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V20 (TIA Portal) (All versions), TIA Portal Cloud V17 (All versions), TIA Portal Cloud V18 (All versions), TIA Portal Cloud V19 (All versions < V5.2.1.1), TIA Portal Cloud V20 (All versions < V5.2.2.2), TIA Portal Test Suite V20 (All versions < V20 Update 4). Affected products do not properly sanitize Interprocess Communication input received through a Windows Named Pipe accessible to all local users. This could allow an authenticated local attacker to cause a type confusion and execute arbitrary code within the affected application. | ||||
| CVE-2023-46280 | 2026-06-09 | 6.5 Medium | ||
| A vulnerability has been identified in Security Configuration Tool (SCT) (All versions), SIMATIC Automation Tool (All versions < V5.0 SP2), SIMATIC BATCH V9.1 (All versions < V9.1 SP2 Upd5), SIMATIC NET PC Software V16 (All versions < V16 Update 8), SIMATIC NET PC Software V17 (All versions), SIMATIC NET PC Software V18 (All versions < V18 SP1), SIMATIC NET PC Software V19 (All versions < V19 Update 2), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC PDM V9.2 (All versions < V9.2 SP2 Upd3), SIMATIC Route Control V9.1 (All versions < V9.1 SP2 Upd3), SIMATIC S7-PCT (All versions < V3.5 SP3 Update 6), SIMATIC STEP 7 V5 (All versions < V5.7 SP3), SIMATIC WinCC OA V3.17 (All versions), SIMATIC WinCC OA V3.18 (All versions < V3.18 P025), SIMATIC WinCC OA V3.19 (All versions < V3.19 P010), SIMATIC WinCC Runtime Advanced (All versions < V17 Update 8), SIMATIC WinCC Runtime Professional V16 (All versions < V16 Update 6), SIMATIC WinCC Runtime Professional V17 (All versions < V17 Update 8), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 17), SIMATIC WinCC V8.0 (All versions < V8.0 Update 5), SINAMICS Startdrive (All versions < V19 SP1), SINEC NMS (All versions < V3.0), SINUMERIK ONE virtual (All versions < V6.23), SINUMERIK PLC Programming Tool (All versions < V3.3.12), TIA Portal Cloud Connector (All versions < V2.0), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 4), Totally Integrated Automation Portal (TIA Portal) V19 (All versions < V19 Update 2), SINEC NMS (All versions < V3.0 SP1). The affected applications contain an out of bounds read vulnerability. This could allow an attacker to cause a Blue Screen of Death (BSOD) crash of the underlying Windows kernel. | ||||
| CVE-2026-47430 | 1 Apache | 1 Cordova In-app-browser | 2026-06-09 | N/A |
| ## Summary The iOS implementation of `cordova-plugin-inappbrowser` passes the `id` field from a `WKScriptMessage` body to `commandDelegate sendPluginResult:callbackId:` with no format validation (`CDVWKInAppBrowser.m:560–574`). Any web content loaded inside the InAppBrowser can fire any pending Cordova callback in the host app by posting a message whose `id` field is a guessable or enumerated callback identifier. An attack abusing this weakness must be tailored to the specific plugins and callback IDs the host app uses. Though an attacker with knowledge of common Cordova plugin configurations could craft reusable payloads targeting widely-adopted plugins. ## Impact An unauthenticated remote attacker who controls content displayed in the InAppBrowser — via a URL the app opens (OAuth redirect, marketing link, deep-link target) or a network interception — can call `window.webkit.messageHandlers.cordova_iab.postMessage({id: '<victim-callback-id>', d: '...'})` to fire callbacks belonging to any other installed Cordova plugin (Camera, Contacts, File, Geolocation). Cordova callback IDs follow the predictable format `<PluginName><sequential-integer>`, making enumeration feasible. Successful exploitation allows the attacker to spoof plugin results across trust boundaries — for example, injecting a forged camera approval, a fabricated contacts list, or a crafted file-read response. This issue affects Cordova Plugin InAppBrowser: from 3.1.0 through 6.0.0. Users are recommended to upgrade to version 6.0.1, which fixes the issue. | ||||
| CVE-2026-22164 | 1 Imaginationtech | 1 Graphics Ddk | 2026-06-09 | 7.5 High |
| Software installed and run as a non-privileged user may conduct improper GPU system calls to corrupt kernel heap memory. By creating resources of certain types and presenting a set of parameters to the affected interface the exploit can be used to corrupt kernel memory. | ||||
| CVE-2026-34194 | 1 Imaginationtech | 1 Graphics Ddk | 2026-06-09 | 7.1 High |
| Software installed and run as a non-privileged user may conduct improper GPU system calls to cause mismanagement of a mapping state maintained for a sparse memory allocation. The product accidentally refers to the wrong memory due to the semantics of how math operations are implicitly scaled across buffers of different sizes. | ||||
| CVE-2026-41448 | 1 Adguard | 1 Adguardhome | 2026-06-09 | 9.4 Critical |
| AdGuard Home, when started with the --glinet flag, contains an authentication bypass vulnerability that allows unauthenticated attackers to gain full admin access by supplying a path traversal sequence in the Admin-Token cookie, exploiting unsanitized string concatenation in the token file path construction within the authglinet middleware. Attackers can craft a request with a traversal payload in the Admin-Token header to redirect file reads to arbitrary paths. | ||||
| CVE-2026-10840 | 1 Redhat | 3 Openshift, Openshift Builds, Openshift Pipelines | 2026-06-09 | 7.1 High |
| A flaw was found in the OpenShift Pipelines operator. The tekton-scheduler-rolebinding ClusterRoleBinding grants the system:authenticated group write access to Kueue and cert-manager custom resources via the tekton-scheduler-role ClusterRole. When Kueue or cert-manager CRDs are present on the cluster, any authenticated user can disrupt workload scheduling, tamper with scheduling priorities, delete other tenants' Workload objects, or induce cert-manager to overwrite TLS Secrets including the default ingress controller certificate. | ||||
| CVE-2026-25112 | 1 Genetec | 7 Genetec Airport Operational Manager, Genetec Industrial Iot, Genetec Inter-system Gateway and 4 more | 2026-06-09 | 7.8 High |
| A high-severity vulnerability in the deployment of Genetec RabbitMQ that allows a privilege escalation attack. | ||||
| CVE-2026-23687 | 2 Sap, Sap Se | 2 Sap Basis, Sap Netweaver And Abap Platform | 2026-06-09 | 8.8 High |
| SAP NetWeaver Application Server ABAP and ABAP Platform allows an authenticated attacker with normal privileges to obtain a valid signed message and send modified signed XML documents to the verifier. This may result in acceptance of tampered identity information, unauthorized access to sensitive user data and potential disruption of normal system usage. | ||||
| CVE-2026-10725 | 1 Crux | 1 Protocol::http2 | 2026-06-09 | 7.5 High |
| Protocol::HTTP2 versions before 1.13 for Perl is vulnerable to a HTTP/2 Bomb. Protocol::HTTP2's inbound HPACK path has no header-list size limit, so a small HTTP/2 request can expand into large server memory (the "HTTP/2 bomb"). The headers_decode method materialises a full key+value copy per indexed reference with no running size check, and the stream_header_block_add method appends (since version 1.12) every CONTINUATION frame to the per-stream buffer unbounded. MAX_HEADER_LIST_SIZE (default 65536) is advertised in SETTINGS but never consulted on decode. It is absent from the decoder and from the :limits export tag. | ||||
| CVE-2025-66329 | 1 Huawei | 2 Emui, Harmonyos | 2026-06-09 | 4 Medium |
| Permission control vulnerability in the window management module. Impact: Successful exploitation of this vulnerability may affect availability. | ||||
| CVE-2025-66274 | 2 Qnap, Qnap Systems | 2 Quts Hero, Quts Hero | 2026-06-09 | 4.9 Medium |
| A NULL pointer dereference vulnerability has been reported to affect several QNAP operating system versions. If a remote attacker gains an administrator account, they can then exploit the vulnerability to launch a denial-of-service (DoS) attack. We have already fixed the vulnerability in the following versions: QTS 5.2.9.3410 build 20260214 and later QuTS hero h5.2.9.3410 build 20260214 and later QuTS hero h5.3.2.3354 build 20251225 and later QuTS hero h6.0.0.3397 build 20260206 and later | ||||
| CVE-2025-59381 | 1 Qnap | 2 Qts, Quts Hero | 2026-06-09 | 4.9 Medium |
| A path traversal vulnerability has been reported to affect several QNAP operating system versions. If a remote attacker gains an administrator account, they can then exploit the vulnerability to read the contents of unexpected files or system data. We have already fixed the vulnerability in the following versions: QTS 5.2.8.3332 build 20251128 and later QuTS hero h5.2.8.3321 build 20251117 and later QuTS hero h5.3.2.3354 build 20251225 and later | ||||
| CVE-2026-11459 | 1 Secureage | 1 Catchpulse | 2026-06-09 | 3.3 Low |
| A security vulnerability has been detected in SecureAge CatchPulse up to 10.9.3. Impacted is an unknown function in the library saappctl.sys of the component IOCTL Handler. The manipulation leads to information disclosure. Local access is required to approach this attack. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way. | ||||