Export limit exceeded: 45775 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (45775 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2025-68113 | 1 Altcha | 1 Altcha | 2026-04-15 | 6.5 Medium |
| ALTCHA is privacy-first software for captcha and bot protection. A cryptographic semantic binding flaw in ALTCHA libraries allows challenge payload splicing, which may enable replay attacks. The HMAC signature does not unambiguously bind challenge parameters to the nonce, allowing an attacker to reinterpret a valid proof-of-work submission with a modified expiration value. This may allow previously solved challenges to be reused beyond their intended lifetime, depending on server-side replay handling and deployment assumptions. The vulnerability primarily impacts abuse-prevention mechanisms such as rate limiting and bot mitigation. It does not directly affect data confidentiality or integrity. This issue has been addressed by enforcing explicit semantic separation between challenge parameters and the nonce during HMAC computation. Users are advised to upgrade to patched versions, which include version 1.0.0 of the altcha Golang package, version 1.0.0 of the altcha Rubygem, version 1.0.0 of the altcha pip package, version 1.0.0 of the altcha Erlang package, version 1.4.1 of the altcha-lib npm package, version 1.3.1 of the altcha-org/altcha Composer package, and version 1.3.0 of the org.altcha:altcha Maven package. As a mitigation, implementations may append a delimiter to the end of the `salt` value prior to HMAC computation (for example, `<salt>?expires=<time>&`). This prevents ambiguity between parameters and the nonce and is backward-compatible with existing implementations, as the delimiter is treated as a standard URL parameter separator. | ||||
| CVE-2024-34710 | 2026-04-15 | 7.1 High | ||
| Wiki.js is al wiki app built on Node.js. Client side template injection was discovered, that could allow an attacker to inject malicious JavaScript into the content section of pages that would execute once a victim loads the page that contains the payload. This was possible through the injection of a invalid HTML tag with a template injection payload on the next line. This vulnerability is fixed in 2.5.303. | ||||
| CVE-2025-6752 | 1 Linksys | 4 Ea7200, Ea7450, Ea7500 and 1 more | 2026-04-15 | 8.8 High |
| A vulnerability has been found in Linksys WRT1900ACS, EA7200, EA7450 and EA7500 up to 20250619 and classified as critical. This vulnerability affects the function SetDefaultConnectionService of the file /upnp/control/Layer3Forwarding of the component IGD. The manipulation of the argument NewDefaultConnectionService leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2025-24318 | 2026-04-15 | 6.8 Medium | ||
| Cookie policy is observable via built-in browser tools. In the presence of XSS, this could lead to full session compromise. | ||||
| CVE-2025-59368 | 1 Asus | 1 Router | 2026-04-15 | N/A |
| An integer underflow vulnerability has been identified in Aicloud. An authenticated attacker may trigger this vulnerability by sending a crafted request, potentially impacting the availability of the device. Refer to the ' Security Update for ASUS Router Firmware' section on the ASUS Security Advisory for more information. | ||||
| CVE-2025-68130 | 1 Trpc | 1 Trpc | 2026-04-15 | N/A |
| tRPC allows users to build and consume fully typesafe APIs without schemas or code generation. Starting in version 10.27.0 and prior to versions 10.45.3 and 11.8.0, a A prototype pollution vulnerability exists in `@trpc/server`'s `formDataToObject` function, which is used by the Next.js App Router adapter. An attacker can pollute `Object.prototype` by submitting specially crafted FormData field names, potentially leading to authorization bypass, denial of service, or other security impacts. Note that this vulnerability is only present when using `experimental_caller` / `experimental_nextAppDirCaller`. Versions 10.45.3 and 11.8.0 fix the issue. | ||||
| CVE-2025-24324 | 2 Intel, Kernel | 2 Ethernet 800 Series Software, Linux Kernel | 2026-04-15 | 2.8 Low |
| Integer overflow or wraparound in the Linux kernel-mode driver for some Intel(R) 800 Series Ethernet before version 1.17.2 may allow an authenticated user to potentially enable escalation of privilege via local access. | ||||
| CVE-2025-24792 | 2026-04-15 | 4.4 Medium | ||
| Snowflake PHP PDO Driver is a driver that uses the PHP Data Objects (PDO) extension to connect to the Snowflake database. Snowflake discovered and remediated a vulnerability in the Snowflake PHP PDO Driver where executing unsupported queries like PUT or GET on stages causes a signed-to-unsigned conversion error that crashes the application using the Driver. This vulnerability affects versions 0.2.0 through 3.0.3. Snowflake fixed the issue in version 3.1.0. | ||||
| CVE-2024-11347 | 2026-04-15 | 7.3 High | ||
| Integer Overflow or Wraparound vulnerability in Lexmark International CX, XC, CS, et. Al. (Postscript interpreter modules) allows Forced Integer Overflow.The vulnerability can be leveraged by an attacker to execute arbitrary code as an unprivileged user. | ||||
| CVE-2025-32014 | 2026-04-15 | N/A | ||
| estree-util-value-to-estree converts a JavaScript value to an ESTree expression. When generating an ESTree from a value with a property named __proto__, valueToEstree would generate an object that specifies a prototype instead. This vulnerability is fixed in 3.3.3. | ||||
| CVE-2025-26789 | 2026-04-15 | N/A | ||
| An issue was discovered in Logpoint AgentX before 1.5.0. A vulnerability caused by limited access controls allowed li-admin users to access sensitive information about AgentX Manager in a Logpoint deployment. | ||||
| CVE-2025-24802 | 2026-04-15 | 8.6 High | ||
| Plonky2 is a SNARK implementation based on techniques from PLONK and FRI. Lookup tables, whose length is not divisible by 26 = floor(num_routed_wires / 3) always include the 0 -> 0 input-output pair. Thus a malicious prover can always prove that f(0) = 0 for any lookup table f (unless its length happens to be divisible by 26). The cause of problem is that the LookupTableGate-s are padded with zeros. A workaround from the user side is to extend the table (by repeating some entries) so that its length becomes divisible by 26. This vulnerability is fixed in 1.0.1. | ||||
| CVE-2025-30742 | 2026-04-15 | 5.3 Medium | ||
| httpd.c in atophttpd 2.8.0 has an off-by-one error and resultant out-of-bounds read because a certain 1024-character req string would not have a final '\0' character. | ||||
| CVE-2024-24784 | 2 Go Standard Library, Redhat | 14 Net\/mail, Advanced Cluster Security, Ceph Storage and 11 more | 2026-04-15 | 7.5 High |
| The ParseAddressList function incorrectly handles comments (text within parentheses) within display names. Since this is a misalignment with conforming address parsers, it can result in different trust decisions being made by programs using different parsers. | ||||
| CVE-2024-8201 | 1 Hitachi | 1 Ops Center Analyzer | 2026-04-15 | 5.4 Medium |
| Cross-Site WebSocket Hijacking vulnerability in Hitachi Ops Center Analyzer (RAID Agent component).This issue affects Hitachi Ops Center Analyzer: from 10.8.0-00 before 11.0.4-00; Hitachi Ops Center Analyzer: from 10.9.0-00 before 11.0.4-00. | ||||
| CVE-2024-8159 | 1 Faronics | 1 Deep Freeze | 2026-04-15 | 6.4 Medium |
| Deep Freeze 9.00.020.5760 is vulnerable to an out-of-bounds read vulnerability by triggering the 0x70014 IOCTL code of the FarDisk.sys driver. | ||||
| CVE-2024-36316 | 1 Amd | 19 Radeon Pro V520, Radeon Pro V620, Radeon Pro V710 and 16 more | 2026-04-15 | 5.5 Medium |
| The integer overflow vulnerability within AMD Graphics driver could allow an attacker to bypass size checks potentially resulting in a denial of service | ||||
| CVE-2024-21953 | 1 Amd | 3 Epyc 8004 Series Processors, Epyc 9004 Series Processors, Epyc Embedded 9004 Series Processors | 2026-04-15 | N/A |
| Improper input validation in IOMMU could allow a malicious hypervisor to reconfigure IOMMU registers resulting in loss of guest data integrity. | ||||
| CVE-2024-36346 | 1 Amd | 2 Instinct Mi300a, Instinct Mi300x | 2026-04-15 | 6 Medium |
| Improper input validation in AMD Power Management Firmware (PMFW) could allow a privileged attacker from Guest VM to send arbitrary input data potentially causing a GPU Reset condition. | ||||
| CVE-2024-36348 | 2026-04-15 | 3.8 Low | ||
| A transient execution vulnerability in some AMD processors may allow a user process to infer the control registers speculatively even if UMIP feature is enabled, potentially resulting in information leakage. | ||||