Export limit exceeded: 48998 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (48998 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2024-50944 | 1 Simplcommerce | 1 Simplcommerce | 2026-04-15 | 9.8 Critical |
| Integer overflow vulnerability exists in SimplCommerce at commit 230310c8d7a0408569b292c5a805c459d47a1d8f in the shopping cart functionality. The issue lies in the quantity parameter in the CartController's AddToCart method. | ||||
| CVE-2025-42909 | 1 Sap | 1 Cloud Appliance Library Appliances | 2026-04-15 | 3 Low |
| SAP Cloud Appliance Library Appliances allows an attacker with high privileges to leverage an insecure S/4HANA default profile setting in an existing SAP CAL appliances to gain access to other appliances. This has low impact on confidentiality of the application, integrity and availability is not impacted. | ||||
| CVE-2025-6761 | 1 Kingdee | 1 Cloud-starry-sky | 2026-04-15 | 7.3 High |
| A vulnerability was found in Kingdee Cloud-Starry-Sky Enterprise Edition 6.x/7.x/8.x/9.0. It has been rated as critical. Affected by this issue is the function plugin.buildMobilePopHtml of the file \k3\o2o\bos\webapp\action\DynamicForm 4 Action.class of the component Freemarker Engine. The manipulation leads to improper neutralization of special elements used in a template engine. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. It is recommended to upgrade the affected component. The vendor explains, that in the fixed release "Freemarker is set to 'ALLOWS_NOTHING_RESOLVER' to not parse any classes." | ||||
| CVE-2024-9348 | 1 Docker | 1 Desktop | 2026-04-15 | N/A |
| Docker Desktop before v4.34.3 allows RCE via unsanitized GitHub source link in Build view. | ||||
| CVE-2024-27158 | 1 Toshibatec | 50 E-studio-2010-ac, E-studio-2015-nc, E-studio-2018 A and 47 more | 2026-04-15 | 7.4 High |
| All the Toshiba printers share the same hardcoded root password. As for the affected products/models/versions, see the reference URL. | ||||
| CVE-2018-25135 | 1 Anviz | 1 Crosschex | 2026-04-15 | 9.8 Critical |
| Anviz AIM CrossChex Standard 4.3.6.0 contains a CSV injection vulnerability that allows attackers to execute commands by inserting malicious formulas in user import fields. Attackers can craft payloads in fields like 'Name', 'Gender', or 'Position' to trigger Excel macro execution when importing user data. | ||||
| CVE-2025-6751 | 1 Linksys | 1 E8450 | 2026-04-15 | 8.8 High |
| A vulnerability, which was classified as critical, was found in Linksys E8450 up to 1.2.00.360516. This affects the function set_device_language of the file portal.cgi of the component HTTP POST Request Handler. The manipulation of the argument dut_language leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2023-50736 | 2026-04-15 | 9 Critical | ||
| A memory corruption vulnerability has been identified in PostScript interpreter in various Lexmark devices. The vulnerability can be leveraged by an attacker to execute arbitrary code. | ||||
| CVE-2023-50734 | 2026-04-15 | 9 Critical | ||
| A buffer overflow vulnerability has been identified in PostScript interpreter in various Lexmark devices. The vulnerability can be leveraged by an attacker to execute arbitrary code. | ||||
| CVE-2024-47887 | 1 Rubyonrails | 1 Rails | 2026-04-15 | 3.7 Low |
| Action Pack is a framework for handling and responding to web requests. Starting in version 4.0.0 and prior to versions 6.1.7.9, 7.0.8.5, 7.1.4.1, and 7.2.1.1, there is a possible ReDoS vulnerability in Action Controller's HTTP Token authentication. For applications using HTTP Token authentication via `authenticate_or_request_with_http_token` or similar, a carefully crafted header may cause header parsing to take an unexpected amount of time, possibly resulting in a DoS vulnerability. All users running an affected release should either upgrade to versions 6.1.7.9, 7.0.8.5, 7.1.4.1, or 7.2.1.1 or apply the relevant patch immediately. One may choose to use Ruby 3.2 as a workaround.Ruby 3.2 has mitigations for this problem, so Rails applications using Ruby 3.2 or newer are unaffected. Rails 8.0.0.beta1 depends on Ruby 3.2 or greater so is unaffected. | ||||
| CVE-2024-36671 | 1 Nodemcu | 1 Nodemcu | 2026-04-15 | 9.8 Critical |
| nodemcu before v3.0.0-release_20240225 was discovered to contain an integer overflow via the getnum function at /modules/struct.c. | ||||
| CVE-2024-33698 | 1 Siemens | 4 Simatic Information Server, Simatic Pcs Neo, Sinec Nms and 1 more | 2026-04-15 | 9.8 Critical |
| A vulnerability has been identified in Opcenter Quality (All versions < V2406), Opcenter RDnL (All versions < V2410), SIMATIC PCS neo V4.0 (All versions), SIMATIC PCS neo V4.1 (All versions < V4.1 Update 2), SIMATIC PCS neo V5.0 (All versions < V5.0 Update 1), SINEC NMS (All versions), SINEMA Remote Connect Client (All versions < V3.2 SP3), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 5), Totally Integrated Automation Portal (TIA Portal) V19 (All versions < V19 Update 3). Affected products contain a heap-based buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to execute arbitrary code. | ||||
| CVE-2025-3947 | 2026-04-15 | 8.2 High | ||
| The Honeywell Experion PKS contains an Integer Underflow vulnerability in the component Control Data Access (CDA). An attacker could potentially exploit this vulnerability, leading to Input Data Manipulation, which could result in improper integer data value checking during subtraction leading to a denial of service. Honeywell recommends updating to the most recent version of Honeywell Experion PKS:520.2 TCU9 HF1 and 530.1 TCU3 HF1. The affected Experion PKS products are C300 PCNT02, C300 PCNT05, FIM4, FIM8, UOC, CN100, HCA, C300PM, and C200E. The Experion PKS versions affected are from 520.1 through 520.2 TCU9 and from 530 through 530 TCU3. | ||||
| CVE-2024-4550 | 1 Lenovo | 5 Thinkstation P360 Workstation Firmware, Thinksystem St50 Firmware, Thinksystem St50 V2 Firmware and 2 more | 2026-04-15 | 6.7 Medium |
| A potential buffer overflow vulnerability was reported in some Lenovo ThinkSystem and ThinkStation products that could allow a local attacker with elevated privileges to execute arbitrary code. | ||||
| CVE-2025-11468 | 1 Python | 1 Cpython | 2026-04-15 | 4.5 Medium |
| When folding a long comment in an email header containing exclusively unfoldable characters, the parenthesis would not be preserved. This could be used for injecting headers into email messages where addresses are user-controlled and not sanitized. | ||||
| CVE-2024-21970 | 1 Amd | 9 Athlon, Athlon 3000, Ryzen and 6 more | 2026-04-15 | 4.4 Medium |
| Improper validation of an array index in the AND power Management Firmware could allow a privileged attacker to corrupt AGESA memory potentially leading to a loss of integrity. | ||||
| CVE-2025-24812 | 2026-04-15 | 6.5 Medium | ||
| A vulnerability has been identified in SIMATIC S7-1200 CPU 1211C AC/DC/Rly (6ES7211-1BE40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1211C DC/DC/DC (6ES7211-1AE40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1211C DC/DC/Rly (6ES7211-1HE40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1212C AC/DC/Rly (6ES7212-1BE40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1212C DC/DC/DC (6ES7212-1AE40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1212C DC/DC/Rly (6ES7212-1HE40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1212FC DC/DC/DC (6ES7212-1AF40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1212FC DC/DC/Rly (6ES7212-1HF40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1214C AC/DC/Rly (6ES7214-1BG40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1214C DC/DC/DC (6ES7214-1AG40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1214C DC/DC/Rly (6ES7214-1HG40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1214FC DC/DC/DC (6ES7214-1AF40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1214FC DC/DC/Rly (6ES7214-1HF40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1215C AC/DC/Rly (6ES7215-1BG40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1215C DC/DC/DC (6ES7215-1AG40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1215C DC/DC/Rly (6ES7215-1HG40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1215FC DC/DC/DC (6ES7215-1AF40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1215FC DC/DC/Rly (6ES7215-1HF40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1217C DC/DC/DC (6ES7217-1AG40-0XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1212 AC/DC/RLY (6AG1212-1BE40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1212 AC/DC/RLY (6AG1212-1BE40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1212 DC/DC/RLY (6AG1212-1HE40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1212 DC/DC/RLY (6AG1212-1HE40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1212C DC/DC/DC (6AG1212-1AE40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1212C DC/DC/DC (6AG1212-1AE40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1212C DC/DC/DC RAIL (6AG2212-1AE40-1XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 AC/DC/RLY (6AG1214-1BG40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 AC/DC/RLY (6AG1214-1BG40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 AC/DC/RLY (6AG1214-1BG40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 DC/DC/DC (6AG1214-1AG40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 DC/DC/DC (6AG1214-1AG40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 DC/DC/DC (6AG1214-1AG40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 DC/DC/RLY (6AG1214-1HG40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 DC/DC/RLY (6AG1214-1HG40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 DC/DC/RLY (6AG1214-1HG40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214C DC/DC/DC RAIL (6AG2214-1AG40-1XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214FC DC/DC/DC (6AG1214-1AF40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214FC DC/DC/RLY (6AG1214-1HF40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 AC/DC/RLY (6AG1215-1BG40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 AC/DC/RLY (6AG1215-1BG40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 AC/DC/RLY (6AG1215-1BG40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 DC/DC/DC (6AG1215-1AG40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 DC/DC/DC (6AG1215-1AG40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215C DC/DC/DC (6AG1215-1AG40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215FC DC/DC/DC (6AG1215-1AF40-5XB0) (All versions < V4.7). Affected devices do not process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device. | ||||
| CVE-2024-33519 | 2026-04-15 | 7.2 High | ||
| A vulnerability in the web-based management interface of HPE Aruba Networking EdgeConnect SD-WAN gateway could allow an authenticated remote attacker to conduct a server-side prototype pollution attack. Successful exploitation of this vulnerability could allow an attacker to execute arbitrary commands on the underlying operating system leading to complete system compromise. | ||||
| CVE-2025-31930 | 2026-04-15 | 8.8 High | ||
| A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions < V2.135), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions < V2.135), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions < V2.135), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions < V2.135), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions < V2.135), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions < V2.135), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions < V2.135). Affected devices contain Modbus service enabled by default. This could allow an attacker connected to the same network to remotely control the EV charger. | ||||
| CVE-2025-42976 | 1 Sap | 2 Netweaver, Netweaver Application Server For Abap | 2026-04-15 | 8.1 High |
| SAP NetWeaver Application Server ABAP (BIC Document) allows an authenticated attacker to craft a request that, when submitted to a BIC Document application, could cause a memory corruption error. On successful exploitation, this results in the crash of the target component. Multiple submissions can make the target completely unavailable. A similarly crafted submission can be used to perform an out-of-bounds read operation as well, revealing sensitive information that is loaded in memory at that time. There is no ability to modify any information. | ||||