Export limit exceeded: 354956 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (354956 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2026-35675 | 2 Phpmyfaq, Thorsten | 2 Phpmyfaq, Phpmyfaq | 2026-05-29 | 8.2 High |
| phpMyFAQ before 4.1.3 contains an authentication bypass vulnerability in the password reset endpoint that allows unauthenticated attackers to reset any user account password without token verification or email confirmation. Attackers can enumerate valid usernames, obtain plaintext passwords via email, and achieve complete account takeover including administrative access. | ||||
| CVE-2026-10061 | 1 Trendnet | 1 Tew-432brp | 2026-05-29 | 6.3 Medium |
| A vulnerability was found in TRENDnet TEW-432BRP 3.10B20. Affected is the function formWPS of the file /goform/formWPS. The manipulation of the argument peerPin results in command injection. The attack can be executed remotely. The exploit has been made public and could be used. The vendor explains: "This product has been EOL for 15 years (since 2009). As the item has been EOL for such a long time, we are not able to replicate or fix any vulnerabilities." This vulnerability only affects products that are no longer supported by the maintainer. | ||||
| CVE-2021-22764 | 1 Schneider-electric | 8 Powerlogic Pm5560, Powerlogic Pm5560 Firmware, Powerlogic Pm5561 and 5 more | 2026-05-29 | 5.3 Medium |
| A CWE-287: Improper Authentication vulnerability exists in PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 and PowerLogic EGX300 (see security notification for version infromation) that could cause loss of connectivity to the device via Modbus TCP protocol when an attacker sends a specially crafted HTTP request. | ||||
| CVE-2021-22763 | 1 Schneider-electric | 10 Powerlogic Pm5560, Powerlogic Pm5560 Firmware, Powerlogic Pm5561 and 7 more | 2026-05-29 | 9.8 Critical |
| A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists in PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 and PowerLogic EGX300 (see security notification for version infromation) that could allow an attacker administrator level access to a device. | ||||
| CVE-2021-22702 | 1 Schneider-electric | 24 Powerlogic Ion7300, Powerlogic Ion7300 Firmware, Powerlogic Ion7400 and 21 more | 2026-05-29 | 5.9 Medium |
| A CWE-319: Cleartext transmission of sensitive information vulnerability exists in PowerLogic ION7400, ION7650, ION7700/73xx, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause disclosure of user credentials when a malicious actor intercepts Telnet network traffic between a user and the device. | ||||
| CVE-2020-7565 | 1 Schneider-electric | 2 Modicon M221, Modicon M221 Firmware | 2026-05-29 | 7.1 High |
| A CWE-326: Inadequate Encryption Strength vulnerability exists in Modicon M221 (all references, all versions) that could allow the attacker to break the encryption key when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller. | ||||
| CVE-2020-7564 | 1 Schneider-electric | 40 Modicon M340 Bmx Noc 0401, Modicon M340 Bmx Noc 0401 Firmware, Modicon M340 Bmx Noe 0100 and 37 more | 2026-05-29 | 6.3 Medium |
| A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists in the Web Server on Modicon M340, Modicon Quantum and Modicon Premium Legacy offers and their Communication Modules (see notification for details) which could cause write access and the execution of commands when uploading a specially crafted file on the controller over FTP. | ||||
| CVE-2020-7563 | 1 Schneider-electric | 40 Modicon M340 Bmx Noc 0401, Modicon M340 Bmx Noc 0401 Firmware, Modicon M340 Bmx Noe 0100 and 37 more | 2026-05-29 | 6.3 Medium |
| A CWE-787: Out-of-bounds Write vulnerability exists in the Web Server on Modicon M340, Modicon Quantum and Modicon Premium Legacy offers and their Communication Modules (see notification for details) which could cause corruption of data, a crash, or code execution when uploading a specially crafted file on the controller over FTP. | ||||
| CVE-2020-7562 | 1 Schneider-electric | 40 Modicon M340 Bmx Noc 0401, Modicon M340 Bmx Noc 0401 Firmware, Modicon M340 Bmx Noe 0100 and 37 more | 2026-05-29 | 6.3 Medium |
| A CWE-125: Out-of-Bounds Read vulnerability exists in the Web Server on Modicon M340, Modicon Quantum and Modicon Premium Legacy offers and their Communication Modules (see notification for details) which could cause a segmentation fault or a buffer overflow when uploading a specially crafted file on the controller over FTP. | ||||
| CVE-2017-7575 | 1 Schneider-electric | 2 Modicon Tm221ce16r, Modicon Tm221ce16r Firmware | 2026-05-29 | 9.8 Critical |
| Schneider Electric Modicon TM221CE16R 1.3.3.3 devices allow remote attackers to discover the application-protection password via a \x00\x01\x00\x00\x00\x05\x01\x5a\x00\x03\x00 request to the Modbus port (502/tcp). Subsequently the application may be arbitrarily downloaded, modified, and uploaded. | ||||
| CVE-2017-7574 | 1 Schneider-electric | 3 Modicon Tm221ce16r, Modicon Tm221ce16r Firmware, Somachine | 2026-05-29 | 10 Critical |
| Schneider Electric SoMachine Basic 1.4 SP1 and Schneider Electric Modicon TM221CE16R 1.3.3.3 devices have a hardcoded-key vulnerability. The Project Protection feature is used to prevent unauthorized users from opening an XML protected project file, by prompting the user for a password. This XML file is AES-CBC encrypted; however, the key used for encryption (SoMachineBasicSoMachineBasicSoMa) cannot be changed. After decrypting the XML file with this key, the user password can be found in the decrypted data. After reading the user password, the project can be opened and modified with the Schneider product. | ||||
| CVE-2017-6030 | 1 Schneider-electric | 6 Modicon M221, Modicon M221 Firmware, Modicon M241 and 3 more | 2026-05-29 | 6.5 Medium |
| A Predictable Value Range from Previous Values issue was discovered in Schneider Electric Modicon PLCs Modicon M221, firmware versions prior to Version 1.5.0.0, Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The affected products generate insufficiently random TCP initial sequence numbers that may allow an attacker to predict the numbers from previous values. This may allow an attacker to spoof or disrupt TCP connections. | ||||
| CVE-2025-48977 | 1 Apache | 1 Ignite | 2026-05-29 | 6.5 Medium |
| Relative Path Traversal vulnerability in Apache Ignite REST API. Authenticated REST API users can read any file on the server with "cmd=log" command and a log path crafted in a certain way. This issue affects Apache Ignite: from 2.0.0 through 2.17.0. Users are recommended to upgrade to version 2.18.0, which fixes the issue. | ||||
| CVE-2026-38702 | 1 Inhandnetworks | 8 Ir302, Ir302 Firmware, Ir305 and 5 more | 2026-05-29 | 9.8 Critical |
| A command injection vulnerability exists in the Admin Access feature of InHand Networks IR302 firmware V3.5.108, IR305 firmware V1.0.118, IR315 firmware V1.0.118, IR615 firmware V1.0.118, and earlier versions. Attackers can exploit this vulnerability to obtain ROOT privileges on remote target devices. | ||||
| CVE-2026-38703 | 1 Inhandnetworks | 8 Ir302, Ir302 Firmware, Ir305 and 5 more | 2026-05-29 | 9.8 Critical |
| A command injection vulnerability exists in the ZeroTier VPN feature of InHand Networks IR302 firmware V3.5.108, IR305 firmware V1.0.118, IR315 firmware V1.0.118, IR615 firmware V1.0.118, and earlier versions. Attackers can exploit this vulnerability to obtain ROOT privileges on remote target devices. | ||||
| CVE-2018-7798 | 1 Schneider-electric | 2 Modicon M221, Somachine Basic | 2026-05-29 | 8.2 High |
| A Insufficient Verification of Data Authenticity (CWE-345) vulnerability exists in the Modicon M221, all versions, which could cause a change of IPv4 configuration (IP address, mask and gateway) when remotely connected to the device. | ||||
| CVE-2026-38707 | 1 Inhandnetworks | 8 Ir302, Ir302 Firmware, Ir305 and 5 more | 2026-05-29 | 9.8 Critical |
| A command injection vulnerability exists in the IPSec VPN feature of InHand Networks IR302 firmware V3.5.108, IR305 firmware V1.0.118, IR315 firmware V1.0.118, IR615 firmware V1.0.118, and earlier versions. Attackers can exploit this vulnerability to obtain ROOT privileges on remote target devices. | ||||
| CVE-2022-4224 | 1 Codesys | 16 Control For Beaglebone Sl, Control For Empc-a\/imx6 Sl, Control For Iot2000 Sl and 13 more | 2026-05-29 | 8.8 High |
| In multiple products of CODESYS v3 in multiple versions a remote low privileged user could utilize this vulnerability to read and modify system files and OS resources or DoS the device. | ||||
| CVE-2026-46526 | 1 Learningcircuit | 1 Local Deep Research | 2026-05-29 | 5 Medium |
| Local Deep Research is an AI-powered research assistant for deep, iterative research. Prior to 1.6.10, the URL checking logic in local-deep-research has a logical flaw that could be bypassed by attackers, leading to SSRF attacks. The current project uses validate_url to validate the input URL. The main logic is to perform security checks on the host portion of the URL extracted by urlparse to prevent SSRF attacks. However, there are indeed differences in parsing between urlparse and the library that actually sends the request. For example, in safe_get, validate_url is first used to perform an SSRF check, and then requests.get is used to send the actual request. This vulnerability is fixed in 1.6.10. | ||||
| CVE-2022-0715 | 1 Schneider-electric | 66 Scl Series 1029 Ups, Scl Series 1029 Ups Firmware, Scl Series 1030 Ups and 63 more | 2026-05-29 | 8.9 High |
| A CWE-287: Improper Authentication vulnerability exists that could cause an attacker to arbitrarily change the behavior of the UPS when a key is leaked and used to upload malicious firmware. Affected Product: APC Smart-UPS Family: SMT Series (SMT Series ID=18: UPS 09.8 and prior / SMT Series ID=1040: UPS 01.2 and prior / SMT Series ID=1031: UPS 03.1 and prior), SMC Series (SMC Series ID=1005: UPS 14.1 and prior / SMC Series ID=1007: UPS 11.0 and prior / SMC Series ID=1041: UPS 01.1 and prior), SCL Series (SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior), SMX Series (SMX Series ID=20: UPS 10.2 and prior / SMX Series ID=23: UPS 07.0 and prior), SRT Series (SRT Series ID=1010/1019/1025: UPS 08.3 and prior / SRT Series ID=1024: UPS 01.0 and prior / SRT Series ID=1020: UPS 10.4 and prior / SRT Series ID=1021: UPS 12.2 and prior / SRT Series ID=1001/1013: UPS 05.1 and prior / SRT Series ID=1002/1014: UPSa05.2 and prior), APC SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior) | ||||